PUMP 2
PUMP 3
press twice
PUMP 1
PUMP 1
20
seconds
20
seconds
START UP GUIDE
CASCADE II
PREP FOR FILLING
FILLING YOUR SPA
1
2
3
4
5
6
7
8
Using a cloth and water, wipe away any
dirt/dust collected from transport. Ensure
all jets are open by turning the face
counter clockwise.
If your spa has a Crystal Clear tube the
threaded plug needs to be on prior to
filling the spa.
Remove the filter lock ring and lid.
Remove filter and take it out of the
plastic transport bag.
Put the filter back inside and secure the
lid firmly with the locking rig. Loosen
air-bleed screw.
Place fill hose inside the spa and fill main
body of spa with water until it reaches the
infinity edge. Allow water to spill over
infinity edge for approximately 60
seconds.
Tighten air-bleed screw.
Turn power to the spa on from GFCI
breaker to activate water level gauge.
Continue filling until the water gauge
reads just below 1/2 full.
Turn power to the spa off from the GFCI
breaker for 30 seconds and then turn
back on.
Do not press the back and/or pump #1
button on the control panel. Activate high
speed on pumps 2 & 3 (if 3-pump model) or
pump 2 (if 2-pump model) by pressing the
pump buttons twice. Let run for 60 seconds.
Continue running pumps 2 & 3 (pump 2
on 2-pump models), turn pump 1 on high
speed for 20 seconds by pressing the
pump 1 icon twice.
Continue running pumps 2 & 3 (pump
2 on 2-pump models) on high speed for
30 seconds and activate pump 1 on
high speed for 20 seconds.
Cascade check valve inside the
equipment area, full of water is an
indication of no more air in the plumbing
line. If the check valve is not full of water,
air is still in the plumbing lines.
! DO NOT USE HOT WATER TO FILL YOUR SPA
! PLEASE READ ALL INSTRUCTIONS BELOW BEFORE FILLING THE SPA
IMPORTANT: Your Infinity Edge Spa will have an additional drain valve that will drain water from the reserve tank. This is separate from the main spa drain system.
! DO NOT USE WATER FROM A WATER SOFTENER
9
10
11
12
ALL PUMPS
PUMP 1
REPEAT
Repeat steps 11-12 until all air has been
removed from the system. If air is still in
the system it will precede water coming
out of the jets when pump 1 is activated.
Turn off all pumps. Then turn main power
off to the spa for 30 seconds. Then turn
power back on.
Your water level should read just
above 1/4 full on the gauge when
pump 1 (high speed) is activated.
Your hot tub is now filled. Set the
temperature and get ready to enjoy!
14
15
16
Release any additional trapped air by
loosening the air bleed screw. Wait for all
air to be released. Retighten.
13
! PLEASE READ ALL INSTRUCTIONS BELOW BEFORE FILLING THE SPA
Содержание CASCADE II 2022
Страница 2: ...2 OWNER S MANUAL CASCADE II 2022 ...
Страница 50: ...WORLD S BEST BUILT SPAS OWNER S MANUAL 2022 CASCADE II ...