background image

CED-301-501-701B Dehumidifier

Installation and Operation Instruction Manual

7

www.coastair-ac.com

Cautions

Cautions

-This appliance can be used by children aged from 8 years and above and person with reduced physical,

sensory or mental capabilities or lack of experience and knowledge if they have been given supervision

or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children

shall not play with the appliance. Cleaning and user maintenance shall not be made by children without

supervision.  (be applicable for the European Countries)

-This appliance is not intended for use by persons (including childern) with reduced physical, sensory or mental

capabilities or lack of experience and knowledge, unless they have been given supervision or instruction

concerning use of the appliance by a person responsible for their safety.  Children should be supervised to

ensure that they do not play with the appliance.(be applicable for other countries except the European

Countries )

-If the supply cord is damaged, it must be replaced by the manufacturer,its service agent or similarly qualified

persons in order to avoid a hazard.

-Prior to cleaning or other maintenance, the appliance must be disconnected from the supply mains.

-Do not install the appliance in a location that may be exposed to combustible gas. If combustible gas

Содержание CED-301B

Страница 1: ...Installation and Operation Instruction Manual Dehumidifier CED 301B CED 501B CED 701B www coastair ac com ...

Страница 2: ...n and Operation Instruction Manual 2 www coastair ac com CONTENTS 1 Contents P r e p a r a ti o n S a fe ty P r e caut ions Ca u ti o n s O p e r a ti o n M a i n te n a n ce 3 13 Fa u l t Di a g nos is Product Disposal 5 6 9 14 15 Warranty 17 ...

Страница 3: ...eration Instruction Manual 3 www coastair ac com PREPARATION 2 Preparation Rear Front Handle both sides Control Panel Air Intake Grille Air Filter behind the grille Water Bucket Power Cord Power Plug Air Outlet Grille Power Cord Band Drain Hose Outlet ...

Страница 4: ...CED 301 501 701B Dehumidifier Installation and Operation Instruction Manual 4 www coastair ac com PREPARATION 3 Preparation NOTE The unit you purchased may be look like one of the following ...

Страница 5: ...eaning turn off the power and unplug the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc Do not drink or use the water drained from the unit Do not take the water bucket out during operation WARNING To prevent death or injury to the user or other people and property damage the following instructions must be followed Incorrect operation due to ign...

Страница 6: ... refer to the nameplate for the electrical data have a qualified electrician install the proper receptacle To avoid the possibility of personal injury always disconnect the power supply to the unit before installing and or servicing All wiring must be performed strictly in accordance with the wiring diagram located on the middle baffle of the unit behind of the water bucket Electrical Information ...

Страница 7: ...ies This appliance is not intended for use by persons including childern with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance be applicable for other count...

Страница 8: ...similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over Do not operate unit with a damaged cord or plug Discard unit or return to an authorized service facility for examination and or repair To reduce the risk of fire or electric shock do not use this fan with any solid state speed control device The appliance shal...

Страница 9: ...the unit will be shut off automatically Wait 3 minutes before resuming operation After the unit has stopped it cannot be restarted in the first 3 minutes This is to protect the unit Operation will automatically start after 3 minutes Auto Defrost When frost builds up on the evaporator coils the compressor will cycle off and the fan will continue to run until the frost disappears Auto Restart If the...

Страница 10: ...s to initiate the Auto start and Auto stop feature in conjuction with the Up and Down buttons Filter button The check filter feature is a reminder to clean the Air Filter for more efficient operation The Filter light Clean filter light will illuminate after 250 hours of operation To reset after cleaning the filter press the Filter button and the light will go off Mode button Press to select the de...

Страница 11: ...ss to initiate the Auto start and Auto stop feature in conjunction with the and buttons When the unit is on first press the Timer button the Timer Off indicator light illuminates It indicates the Auto Stop program is initiated Press it again the Time On indicator light illuminates It indicates the Auto Start is initiated When the unit is off first press the Timer button the TIMER ON indicator ligh...

Страница 12: ...it and unplug the power cord Contact the manufacturer or its service agents or a similar qualified person for service Removing the collected water There are two ways to remove collected water 1 Use the bucket When the bucket is full remove the bucket and empty it water outlet 2 Continuous draining Water can be automatically emptied into a floor drain by attaching the unit with a water hose Id Φ 5 ...

Страница 13: ...Drain hose subassembly Connector Drain hose Plastic cover Water hose Female threaded end Band Power cord Maintenance Care and cleaning of the dehumidifier WARNING Turn the dehumidifier off and remove the plug from the wall outlet before cleaning 1 CAUTION DO NOT operate the dehumidifier without a filter because dirt and lint will clog it and reduce performance or 2 Clean the bucket Clean the bucke...

Страница 14: ...e to connector or hose connection may be loose When using the bucket to collect water the back drain plug is removed This is normal The unit has Auto defrost feature Did not allow enough time to remove the moisture Make sure there are no curtains blinds or furniture blocking the front or back of the dehumidifier The humidity selector may not be set low enough Check that all doors windows and other...

Страница 15: ...ld waste For disposal there are several possibilities A The municipality may have established collection systems where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer may take back the old product at least free of charge C The manufacture may take back the old appliance for disposal at least free of charge to the user D As old produc...

Страница 16: ...CED 301 501 701B Dehumidifier Installation and Operation Instruction Manual 16 www coastair ac com THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 17: ... warranty period Without this proof the express warranty begins on the date of shipment from the factory REMEDY PROVIDED BY THE LIMITED EXPRESS WARRANTY The sole remedy under the Limited Warranty is replacement of the defective unit Labor to diagnose and replace the defective unit is not covered by this Limited Express Warranty If for any reason the replacement product is no longer available durin...

Страница 18: ...www coastair ac com 12 2018 ...

Отзывы: