Connect the flue to the fire making sure that the
connection is airtight, using rope seal and cement. (See
Fig. 10)
Before commencing installation check that the local
distribution conditions (identification of type of gas and
pressure) and the adjustment of the appliance are
compatible. Installation may be made easier with the
removal of the front door. (See Fig. 11).
It is recommended that the cast fire is fitted into position
and the flue connection made and checked before the
firebed is installed.
Position the appliance in accordance with the instructions
given in the section ‘LOCATION’ and connect the flue
pipe in accordance with the section ‘THE FLUE’.
FLEXIBLE PIPE/CONNECTIONS MUST NOT BE USED.
Prior to the installation of the Rembrandt 18G/L Gas
Burner into the fire decide which side the gas supply is to
enter the appliance and remove the push in button. This
is to allow for the positioning of the 8mm copper gas
supply pipe before connection is made between the
appliance and the isolating tap. Remove 2 fixing brackets.
(See Fig. 12) from the underside of the firebed - this will
make fitting easier.
Fit the restrictor/pressure test elbow to the gas inlet pipe
on the fired bed positioning to the left or right depending
on chosen gas route.
FLUE CONNECTION
FIG. 10
DESN 512269
INSTALLING THE APPLIANCE
FIG. 11
DESN 512258
FIG. 12
DESN 512265