4.2 TECHNICAL SPECIFICATIONS CNC18-CNC75 (230/1/60)
D R Y E R M O D E L
CNCM10
CNCM18
Air flow rate at nominal condition
1
[scfm]
[Nl/min]
[Nm
3
/h]
10
285
17
15
425
26
Pressure DewPoint at nominal condition
1
[°F - °C]
38 – 3.3
Nominal ambient temperature
[°F - °C]
100 - 37.8
Max. ambient temperature
[°F - °C]
115 – 45
Min. ambient temperature
[°F - °C]
34 – 1
Nominal inlet air temperature
[°F - °C]
100 - 37.8
Max. inlet air temperature
[°F - °C]
115 – 45
Nominal inlet air pressure
[psig – barg]
100 - 6.9
Max. inlet air pressure
[psig - barg]
232 – 16
Max. outlet air pressure drop -
∆
p
[psi – bar]
4.4 - 0.3
Inlet-outlet air connection
Copper pipe OD 3/8 in. (9.52 mm)
Refrigerant type
R134.a (HFC) - CH
2
F-CF
3
Refrigerant charging
[oz – g]
6.1/8 - 175
12.3/8 - 350
Cooling air capacity
[cfm - m
3
/h]
120 - 200
200 - 340
Power supply
[Phase/V/Hz]
230/1/60
Nominal electric consumption
[A]
1.1
1.4
Max. electric consumption
[A]
1.5
1.7
Compressor power
[HP]
1/8
1/5
Weight
[lbs - kg]
62 - 28
68 - 31
Max. noise level
< 70 dbA at 40in (1m)
1
The nominal condition refers to an ambient temperature of 100°F with inlet air at 100 psig and 100°F
Inches mm
A 14.562 370
B 17.625 449
C 17.437 443
D 2.500
65
E 1.375
35
F 2.00 51
G 2.750
69
H 15.562 395
I 1.062 27
J 2.437 62
K .375
10
L 1.00 26
M .562
14
1-Rocker On/Off Switch-Illuminated
2-Power Supply Cord
3-Condensate Drain