Co2meter CM-0001 Скачать руководство пользователя страница 14

Sampling Data Logger User’s Manual

 

CO2Meter.com

 

 

 

PAGE 

14

of 

17

 

Appendix

 

Meter Specifications 

 

CO2

 

Sensor

 

Performance

 

and

 

Ratings

 

Sensor

 

Type

 

Non‐dispersive infrared 
(NDIR) 

Measuring

 

Range

 

0‐10,000 ppm (1% CO2) 
0‐50,000 ppm (5% CO2) 
0‐30% vol. (30% CO2) 
0‐60% vol. (60% CO2) 
0‐100% vol.  (100% CO2) 

Accuracy

 

±30 ppm, ±5% of measured 
value 

Repeatability

 

±20 ppm, ±1% measured 
value (1% models) 
±0.1%, ±2% of measured 
value (all other models) 

General

 

Warm

up

 

Time

 

<1 min. (instant 
measurements) 

Life

 

Expectancy

>15 years

Maintenance

 

Interval

 

No maintenance required 

Data

 

Logging

 

Data

 

Points

60,000

Programmable

Interval

 

Data

 

Date, time, CO2, O2 (every 15 
seconds to 18 hours) 

 

Pump

 

Characteristics

 

Max.

 

Flow

 

(STP)

 

500 ml/min @ STP

Max.

 

Vacuum

150 mbar

Max.

 

Pressure

500 mbar

Max.

 

System

 

Pressure

 

~101.3 KPa (1 atm.)

Life

 

Expectancy

1,000 (standard), depending 
on sampling interval 

Power

 

Input

 

Voltage

6 VDC

Method

 

Power supply or 4x AA 
batteries 

Power

Consumption

 

~0.5 Watt. Avg. (pump 
running) 

Dimensions

 

WxHxD

in(mm) 4.8(122) x 7.1(181) x 2.1(55) 

 

 

 

Содержание CM-0001

Страница 1: ...M 0002 CM 0003 CM 0050 CM 0056 See Table 1 on page 7 for details WARNING Install our complimentary GasLab software before connecting your CO2Meter product s to your computer Failure to do so may affec...

Страница 2: ...mplimentary GasLab software before connecting your CO2Meter product s to your computer Failure to do so may affect the ability for GasLab to detect your meter If this happens please follow the instruc...

Страница 3: ...INSTRUMENT OVERVIEW 8 LCD DISPLAY 8 QUICK START GUIDE 9 POWERING THE METER 9 OPERATION 9 CONNECTING THE METER TO YOUR PC 9 DATA STORAGE 10 DATA LOGGING 10 SETTINGS 11 DISPLAY SETTINGS 11 PORT SETTINGS...

Страница 4: ...community CO2Meter Inc appreciates your business and looks forward to working with you and your team in the future Please take some time to read through this manual in order to become familiar with th...

Страница 5: ...Optional Accessories If the meter is to operate in environments where humidity is very high 95 RH an Extreme Moisture Filter CM 0103 can be purchased separately This filter will allow free flow of sa...

Страница 6: ...T is not supported on Media Center or Tablet editions Installer will optionally install NET Framework Visit www co2meter com pages downloads to download our complimentary GasLab software to your compu...

Страница 7: ...d on user selected time intervals Scientific devices such as this sampling meter require users to have intimate knowledge of the meter s features limitations operation required software and specificat...

Страница 8: ...percentage format for all other models Logging ON OFF Percentage of free memory Display Shows CO2 concentration level data logging and free memory space Power Jack Connect included power supply Power...

Страница 9: ...iod of time batteries should be removed to prevent damage due to potential battery leakage The POWER switch on the left side of the meter turns the unit ON OFF The LOG switch on the right side of the...

Страница 10: ...fer to the GasLab User s Manual for more information Data Logging These models feature an internal memory capable of storing data when not connected to a computer This allows you to simultaneously rea...

Страница 11: ...ere you can change the date and time on the meter for more accurate reference on the records The default time of your meter could vary depending on your location Review these settings before you start...

Страница 12: ...jolted or otherwise mechanically disturbed the sensor can drift requiring recalibration All calibration procedures follow a single point calibration routine that effectively shifts the zero point of...

Страница 13: ...or if readings vary greatly 5 60 and 100 Sampling Data Logger These models do not feature Automatic Background Calibration ABC algorithm due to the CO2 scale they measure To ensure the highest accurac...

Страница 14: ...other models General Warm up Time 1 min instant measurements Life Expectancy 15 years Maintenance Interval No maintenance required Data Logging Data Points 60 000 Programmable Interval Data Date time...

Страница 15: ...set For more troubleshooting tips on GasLab software see its manual located at www co2meter com pages downloads USB Driver Installation Instructions To install the appropriate USB port drivers compati...

Страница 16: ...jected to misuse neglect accident modifications or repairs by you or by a third party No employee or reseller of CO2Meter com s products may alter this warranty verbally or in writing Liability All li...

Страница 17: ...7 of 17 Contact Us We are here to help For information or technical support please contact us support co2meter com 386 256 4910 Technical Support 386 872 7665 Sales www co2meter com Address CO2Meter I...

Отзывы: