Modbus / RS-485 

The

 

sensor

 

support

 

MODBUS

 

protocols

 

over

 

RS

485,

 

unidirectional

 

transmission

 

at

 

9600kbps.

 

Address

 

0

 

or

 

FE.

 

The

 

following

 

Modbus

 

registers

 

are

 

available:

 

 

Input Registers 

1.

 

O2

 

Value,

 

x10

 

2.

 

Raw

 

ADC

 

Value

 

Holding Registers 

1.

 

O2

 

Span

 

Value

 

(4

 

byte

 

floating

 

number,

 

part

 

1)

 

2.

 

O2

 

Span

 

Value

 

(4

 

byte

 

floating

 

number,

 

part

 

2)

 

3.

 

O2

 

Pot

 

Value

 

4.

 

4

20mA

 

output

  

Zero

 

Value

 

5.

 

4

20mA

 

output

 

Span

 

Value

 

(4

 

byte

 

floating

 

number,

 

part

 

1)

 

6.

 

4

20mA

 

output

 

Span

 

Value

 

(4

 

byte

 

floating

 

number,

 

part

 

2)

 

7.

 

Control

 

Register

 

8.

 

Status

 

Register

  

 

The

 

following

 

commands

 

are

 

available:

 

0x03

 

 

Read

 

Holding

 

Register

 

0x04

 

 

Read

 

Input

 

Register

 

0x06

 

 

Write

 

Holding

 

Register

 

 

Powering the Unit 

The

 

unit

 

can

 

be

 

powered

 

by

 

hardwiring

 

24

 

VDC

 

power

 

through

 

the

 

MDCM

4FP

2M

 

Cable

 

(included)

 

but

 

sampling

 

units

 

can

 

also

 

be

 

powered

 

by

 

the

 

included

 

24VDC

 

International

 

wall

 

power

 

supply.

 

 

LCD Display  

The

 

Liquid

 

Crystal

 

Display

 

(LCD)

 

screen

 

shows

 

the

 

following

 

features:

 

 

CO2

 

in

 

percentage

 

format

 

(##.##%)

 

for

  

100%

 

Содержание TR250Z

Страница 1: ...User Manual TR250Z Oxygen Sensor CM 0134 25 O2 Transmitter CM 0134 WT 25 O2 Transmitter with Tube Sampling CM 0150 25 O2 with Mount Shield CM 0160 95 O2 Transmitter CM 0160 WT 95 O2 Transmitter with T...

Страница 2: ...ESCRIPTION 6 STANDARD OPERATION 7 ENTERING THE SERVICE MENU 7 PERFORMING AN ATMOSPHERIC SPAN CALIBRATION 7 PERFORMING A 0 OXYGEN ZERO POINT CALIBRATION 8 TERMINAL CONNECTORS 8 0 10V OUTPUT OPTIONAL 8...

Страница 3: ...ree Once you download and install the software you can use the Check for updates function under the Help menu to search for new updates Please also pay special attention to the important safeguards sh...

Страница 4: ...easured value 0 95 O2 0 02 1 of measured value Accuracy 25 95 2 full scale Power Supply Maximum Voltage 24VDC Minimum Voltage 20VDC Power Consumption 600mA 24VDC Sensor Ratings Life Expectancy 15 year...

Страница 5: ...ow http www co2meter com pages downloads IMPORTANT MAKE SURE TO INSTALL SOFTWARE BEFORE CONNECTING YOUR DEVICE TO YOUR COMPUTER By installing our software first you will ensure that the proper driver...

Страница 6: ...ower right corner of the unit on the main PCB and are labeled S E and P S LED Status LED Blinks every time a complete measurement cycle is performed and the value is updated Serve s as a heartbeat for...

Страница 7: ...be customized before shipment but by default will be 1 2 3 The buttons must be pressed within a half second of each other else the unit will return to standard operating mode When in the service menu...

Страница 8: ...menu 7 Press 2 to enter the Oxygen submenu 8 Press 1 to calibrate 9 Press 3 to escape Terminal Connectors 1 VDC G G 2 O2 4 20mA SIG GND 3 RS 485 INTERFACE A B GND 4 RESET RST 0 10V Output Optional To...

Страница 9: ...4 4 20mA output Zero Value 5 4 20mA output Span Value 4 byte floating number part 1 6 4 20mA output Span Value 4 byte floating number part 2 7 Control Register 8 Status Register The following command...

Страница 10: ...mechanically disturbed the sensor can drift requiring recalibration All calibration procedures follow a single point calibration routine that effectively shifts the zero point of the O2 sensor Calibr...

Страница 11: ...the calibration tab for the desired gas located in the Configure Sensor screen As long as the gas concentration is stable the unit should instantly reflect the calibrated value This can be confirmed...

Страница 12: ...ller of CO2Meter com s products may alter this warranty verbally or in writing Returns If the product fails under normal use during the warranty period an RMA Return Material Authorization number must...

Страница 13: ...of time lost sales or loss or damage to data injury to person or personal property or any other indirect damages as the result of use of our products Contact Us We are here to help If the troubleshoo...

Отзывы: