CO2 Meter TR250Z Скачать руководство пользователя страница 6

TR250Z Oxygen Transmitter – Manual

 

CO2Meter.com

 

Rev.  27 April, 2015 

Pg. 6 of 13

 

 

 

Install

 

DAS

 

online

 

(Internet

 

Explorer

 

9

 

shown)

 

Quick Start Guide 

Make

 

sure

 

you

 

read

 

through

 

these

 

instructions

 

thoroughly

 

before

 

using

 

your

 

meter.

 

This

 

guide

 

will

 

help

 

you

 

familiarize

 

with

 

your

 

meter

 

in

 

order

 

to

 

be

 

as

 

productive

 

as

 

you

 

need

 

to

 

be

 

in

 

the

 

least

 

amount

 

of

 

time

 

possible.

 

Description 

Display

 

 

Main

 

interface

 

to

 

view

 

current

 

sensor

 

readings

 

and

 

menu

 

state.

 

Will

 

blink

 

“STRT”

 

upon

 

applying

 

power

 

while

 

the

 

sensor

 

warms

 

up

 

and

 

stabilizes.

  

LEDs

 

 

 

are

 

in

 

for

 

lower

 

right

 

corner

 

of

 

the

 

unit

 

on

 

the

 

main

 

PCB

 

and

 

are

 

labeled

 

S,

 

E

 

and

 

P.

 

S

 

LED

 

 

Status

 

LED.

 

Blinks

 

every

 

time

 

a

 

complete

 

measurement

 

cycle

 

is

 

performed

 

and

 

the

 

value

 

is

 

updated.

 

Serve’s

 

as

 

a

 

heartbeat

 

for

 

transmitter

 

operation.

  

E

 

LED

 

 

Error

 

LED.

 

Will

 

light

 

if

 

any

 

abnormal

 

conditions

 

are

 

detected

 

within

 

the

 

device,

 

primarily

 

the

 

sensor

 

falling

 

out

 

of

 

its

 

recommended

 

operating

 

specifications

 

will

 

trigger

 

this

 

lamp.

 

P

 

LED

 

 

Power

 

LED.

 

Will

 

be

 

on

 

continuously

 

when

 

power

 

is

 

applied

 

to

 

the

 

unit.

  

Buttons

 ‐

 

The

 

unit

 

has

 

three

 

surface

 

mount

 

buttons

 

above

 

the

 

LEDs

 

on

 

the

 

PCB.

 

They

 

can

 

be

 

gently

 

and

 

carefully

 

pressed

 

with

 

your

 

finger.

 

These

 

buttons

 

allow

 

you

 

to

 

access

 

all

 

aspects

 

of

 

sensors

 

operation

 

and

 

test

 

or

 

calibrate

 

different

 

functional

 

modules.

 

Содержание TR250Z

Страница 1: ...User Manual TR250Z Oxygen Sensor CM 0134 25 O2 Transmitter CM 0134 WT 25 O2 Transmitter with Tube Sampling CM 0150 25 O2 with Mount Shield CM 0160 95 O2 Transmitter CM 0160 WT 95 O2 Transmitter with T...

Страница 2: ...ESCRIPTION 6 STANDARD OPERATION 7 ENTERING THE SERVICE MENU 7 PERFORMING AN ATMOSPHERIC SPAN CALIBRATION 7 PERFORMING A 0 OXYGEN ZERO POINT CALIBRATION 8 TERMINAL CONNECTORS 8 0 10V OUTPUT OPTIONAL 8...

Страница 3: ...ree Once you download and install the software you can use the Check for updates function under the Help menu to search for new updates Please also pay special attention to the important safeguards sh...

Страница 4: ...easured value 0 95 O2 0 02 1 of measured value Accuracy 25 95 2 full scale Power Supply Maximum Voltage 24VDC Minimum Voltage 20VDC Power Consumption 600mA 24VDC Sensor Ratings Life Expectancy 15 year...

Страница 5: ...ow http www co2meter com pages downloads IMPORTANT MAKE SURE TO INSTALL SOFTWARE BEFORE CONNECTING YOUR DEVICE TO YOUR COMPUTER By installing our software first you will ensure that the proper driver...

Страница 6: ...ower right corner of the unit on the main PCB and are labeled S E and P S LED Status LED Blinks every time a complete measurement cycle is performed and the value is updated Serve s as a heartbeat for...

Страница 7: ...be customized before shipment but by default will be 1 2 3 The buttons must be pressed within a half second of each other else the unit will return to standard operating mode When in the service menu...

Страница 8: ...menu 7 Press 2 to enter the Oxygen submenu 8 Press 1 to calibrate 9 Press 3 to escape Terminal Connectors 1 VDC G G 2 O2 4 20mA SIG GND 3 RS 485 INTERFACE A B GND 4 RESET RST 0 10V Output Optional To...

Страница 9: ...4 4 20mA output Zero Value 5 4 20mA output Span Value 4 byte floating number part 1 6 4 20mA output Span Value 4 byte floating number part 2 7 Control Register 8 Status Register The following command...

Страница 10: ...mechanically disturbed the sensor can drift requiring recalibration All calibration procedures follow a single point calibration routine that effectively shifts the zero point of the O2 sensor Calibr...

Страница 11: ...the calibration tab for the desired gas located in the Configure Sensor screen As long as the gas concentration is stable the unit should instantly reflect the calibrated value This can be confirmed...

Страница 12: ...ller of CO2Meter com s products may alter this warranty verbally or in writing Returns If the product fails under normal use during the warranty period an RMA Return Material Authorization number must...

Страница 13: ...of time lost sales or loss or damage to data injury to person or personal property or any other indirect damages as the result of use of our products Contact Us We are here to help If the troubleshoo...

Отзывы: