6. The LED displays
Display
Charge setting
Note
STANDBY
Charging has not commenced
Connection error, no charging
Setting 1, low charge
Setting 1 (14.4 V/0.8 A)
Setting 2, high charge
Setting 2 (14.4 V/4 A)
Setting 3, high charge
Setting 3 (14.7 V/4 A)
Connection error
Incorrect polarity, check
Charging
Charging commenced
Conservation charging
Battery fully charged
7. Care and maintenance
Cleaning: Remove plug from socket and wipe the device with a soft cloth and possibly
a mild cleaning solution. Never use abrasive cleaners or solvents.
8. Disposal
When you dispose of the product it should be done in accordance with local regulations.
If you are unsure of how to proceed, please contact the local authorities.
9. Specifications
Power supply
220–240 V AC, 50/60 Hz
Effect
0.7 A RMS (65 W)
Discharging
< 5 mA (not connected to 230 V AC)
Max voltage charge
14.4 V (±0.25 V) or 14.7 V (± 0.25 V)
Charging
4.0 A (± 10 %) or 0.8 A (± 10 %)
Ripple
150 mV (max)
Battery types
12 V chargeable lead batteries with capacity 1.2 Ah to 120 Ah
Sealing
IP65
Noise
< 50 dB (test at distance of 500 mm)
Dimensions
180 × 60 × 45 mm
Weight
0.5 kg