6.3.2
DC fuses
6.3.2.1
Automatic fuses (Applicable for part number VDL 6070-NN-10)
All VDL 6000/FASS with part number VDL 6070-NN-10 includes a number of (depending on configuration) automatic
fuses located on the rear side.
When a fuse is blown, the reason for this must always be investigated before the fuse is restored (this is done by pushing the
knob of the fuse back into un-blown position).
6.3.2.2
Glass tube fuses (Applicable for all other part numbers)
All VDL 6000/FASS with part number VDL 6070-NN-11, -12, -13… and VDL 6500-NN includes a number of (depending
on configuration) glass tube fuses located on the rear side.
When a fuse is blown, the reason for this must always be investigated before the fuse is replaced.
All DC fuses are 5x20mm 5A fast glass tube fuses. One spare fuse is mounted on the rear side.