C (G)-310 Main Frame Connector
- 10
7.4
When wiring has been completed, remove
the temporary mounting brackets and reassemble
the connector base to its regular mounting bracket.
Be sure to reconnect the short ground strap between
the no. 10 screw ground terminal on the connector base,
and the screw on the mounting bracket (Figure 4).
7.5
After the connector has been stubbed,
complete the installation by following the
instructions for grounding, splicing, and changing
stub positions given in Sections 5 and 6.
NOTES:
1. Test Field - 100 Tip/Ring pair test receptacles, 50 at
top and 50 at the bottom of the connector base.
2. Connector Field - Receptacles for 100 connector
modules.
3. Jumper Field - 100 Tip/Ring pair wire-wrap terminals
adjacent to integral fanning strip.
8. Marking and Jumpering
8.1 Test fields
: Each connector panel test field
is permanently pre-marked in black numbers in
increments of five pairs (Figure 12). Each pair of
test contacts has tip-left and ring-right. A space is
provided immediately above the bottom test field
to mark the cable number and pair count (Figure
12).