Страница 1: ...___________________________________________________________________________ User s Manual Page i USER S MANUAL VER 1 C82 MULTIFUNCTION CNC BOARD Rev 3 2 MARCH 2020...

Страница 2: ...COM for the inputs of port_1 and port_2 5 JUMPER POSITION 6 5 1 Selecting the SCHP operation mode 6 5 2 Jumper configuration driver enable 7 5 3 Jumper configuration driver fault 7 5 4 Configuration j...

Страница 3: ...FD Fault Driver Fault Optoisolated inputs working at 5 24VDC Outputs can be 500mA open collector or 5vdc at 50mA TTL Buffered outputs Electromechanical Relay with NO and NC positions for general purpo...

Страница 4: ...NS OPTOISOLATED DIGITAL INPUT TTL SPECIFICATIONS On state voltage range 5 to 24VDC Maximum off state voltage 0 8V Typical signal delay 2 8uS DIGITAL OUTPUT TTL SPECIFICATIONS Maximum output voltage 5V...

Страница 5: ...r terminal The board requires an external power supply which can deliver 10 24VDC 700mA to power the logic of the board and the ESS or ETHER MACH but keep in mind that each output can deliver up to 50...

Страница 6: ...______________________________________________________ User s Manual Page 4 4 4 Input terminals for port_1 and port_2 These terminals support signals 5 24VDC you can connect sensors NPN PNP switches c...

Страница 7: ..._________________________________________________ User s Manual Page 5 4 5 Select JUMPER COM for the inputs of port_1 and port_2 Set the Jumper to COM 5VDC GND or 10 24VDC to determine the common for...

Страница 8: ...on the board then the output of the terminals will be active while the Safety Charge Pump signal is present and inactive while the SCHP is not present 1 2 SCHP ON 2 3 SCHP OFF Note also that Relay3 o...

Страница 9: ...________________________________________________________ User s Manual Page 7 5 2 Jumper configuration driver enable 1 2 Driver enable ON 2 3 Driver enable OFF 5 3 Jumper configuration driver fault 1...

Страница 10: ...__________________________ ___________________________________________________________________________ User s Manual Page 8 CONNECTION EXAMPLE FOR SHIELD C78 6 1 RJ45 shield C78 connection for axes Li...

Страница 11: ...er s Manual Page 9 6 3 Pinout RJ45_7 RJ45_8 RJ45_9 RJ45_10 RJ45 PIN P P PIN RJ45 PIN P P PIN RJ45 PIN P P PIN RJ45 PIN P P PIN 1 GND 1 GND 1 GND 1 GND 2 5VDC 2 1_13 2 NC 2 2_17 3 NC 3 1_12 3 NC 3 2_16...

Страница 12: ..._________________________________________ ___________________________________________________________________________ User s Manual Page 10 7 0 CONNECTION EXAMPLE FOR SHIELD C77 7 1 Terminal Shield Sc...

Страница 13: ...rd manual E STOP TERMINAL Connect an E STOP push button as is shown in the below images Pin 10 port 1 is used for E Stop Since this board controls the enable line and the enable line is the one respon...

Страница 14: ...________________________________________________________________________ User s Manual Page 12 TYPICAL CONNECTIONS Wiring inputs using an external 10 30VDC power supply to keep input circuit isolated...

Страница 15: ...ATOR The standby LED lights indicate that the system is ready but disabled When Status LED Green LED lights it indicates that the system is enabled There are 4 possible error sources a driver fault E...

Страница 16: ...Page 14 For the Variable speed control go to http cnc4pc com Tech_Docs VARIABLE_SPEED_CONTROL pdf For Configure the control software go to http cnc4pc com Tech_Docs CONFIGURATION_OF_CONTROL_SOFWARE p...