6
E)
"
NC
","
C
"
,
"
NO
"
for the generator dry node contacts.
"
NC
"
for the
normally closed contact and
"
C
"
for the common contact.
"
NO
"
is
normally an open contact.
4.Precautions
Do not reverse the battery cables. If reversed, the inverter will not be damaged and
can reboot without any reaction.
Do not reverse the PV inputs. If reversed, it will not damage the MPPT Controller.
The MPPT Controller will have no reaction but charging will not be performed.
When connecting the ”AC OUT”, the total power load should not be more than the
rated power of the inverter. This could permanently damage the inverter. If it is an
inductive or capacitive load, reduce power consumption to avoid exceeding the peak
power of the inverter.
When connecting in parallel, connect the
"
L
"
terminal from AC OUT together and
connect
"
N
"
terminal from the AC OUT together as well. There must not be a
connection error! Otherwise, it will cause damage to the inverter.
When connecting in series, the 3 inverters need the
"
N
"
from the AC OUT to be
connected together. 3pcs
"
L
"
constitutes a three-phase output. There must not be a
connection error! Otherwise, it will cause damage to the inverter.