background image

2       Online Instructions: c-m-p.com/tech

IMPORTANT WARNINGS & SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

•  Read this manual completely before attempting installation. Failure to install in accordance with the installation 

instructions could void warranty and result in injury or death.

•  All permanent electrical connections should be made by a qualified electrician.

•  A pressure wire connector, labeled “bonding lug”, is provided on the outside of the unit to permit connection 

to a minimum No. 6 AWG (13.3 mm

2

) solid bonding conductor between this point and any metal equipment, 

metal enclosures of electrical equipment, metal water pipes, or conduit within 5 feet (1.5 meters) of the unit as 
needed to comply with local requirements.

•  Install at least 5 feet (1.5 meters) from wall of pool. Install ozone generator no less than one (1) foot above 

maximum water level to prevent water from contacting electrical equipment. Install in accordance with the 
installation instructions.

•  Follow all applicable electrical codes.

• 

DANGER

ELECTRIC SHOCK HAZARD: 

Be sure to turn power OFF and disconnect from power source 

before any service work is performed. Failure to do so could result in serious injury or death.

•  The DEL AOP

®

 50 must be installed in an outdoor location, or indoors in a forced air ventilated room, and 

installed so that the orientation is exactly as shown in Figure 1. Install to provide water drainage of generator to 
protect electrical components.

•  Mount the DEL AOP

®

 50 so that it is inaccessible to anyone in the pool. Never attempt any servicing while unit 

is wet.

• 

WARNING

Short-term inhalation of high concentrations of ozone and long term inhalation of low 

concentrations of ozone can cause serious harmful physiological effects. DO NOT inhale ozone gas produced 
by this device.

• 

DANGER

For your safety, do not store or use gasoline, chemicals or other flammable liquids or vapors 

near this or any other appliance.

• 

NOTICE

 To maintain cosmetic integrity, protect this unit from direct prolonged sunlight exposure.

• 

WARNING

To reduce the risk of injury, do not permit children to use this product, unless they are closely 

supervised at all times.

• 

WARNING

If unit is not operated according to instructions, high dosages of harmful substances may 

potentially be released.

•  ENVIRONMENTAL NOTICE - 

Hg-Lamp CONTAINS MERCURY. Manage in accordance with disposal laws. See: 

www.lamprecycle.org.

SAVE THESE INSTRUCTIONS!

Содержание DEL AOP 50

Страница 1: ...4 2835 01 Rev A C M P COM DEL DEL AOP 50 OZONE UPGRADE SERVICE INSTRUCTIONS ...

Страница 2: ...e before any service work is performed Failure to do so could result in serious injury or death The DEL AOP 50 must be installed in an outdoor location or indoors in a forced air ventilated room and installed so that the orientation is exactly as shown in Figure 1 Install to provide water drainage of generator to protect electrical components Mount the DEL AOP 50 so that it is inaccessible to anyo...

Страница 3: ...TENTS Covered by one or more U S patents or pending patent applications See c m p com patents for details AOP 50 Preparation 4 Removing the Ozone Generator Subassembly 4 Installing the New Ozone Generator Subassembly 5 Initial System Start Up 5 ...

Страница 4: ...cid may be present in the tubing Wear proper safety equipment gloves and eye protection and avoid direct contact with any condensation in the line REMOVING THE OZONE GENERATOR SUBASSEMBLY 1 Loosen tubing clamp and disconnect the ozone gas line from the injector tube adapter 2 Disconnect the ozone module power connectors 6 from the wire harness 3 Loosen the terminal block from the ozone bracket by ...

Страница 5: ... wire harness 4 Connect the new longer ozone gas line to the injector tube adapter and secure with tubing clamp The ozone gas line contains a check valve install so that the arrow on the check valve points towards the injector tube adapter 5 Connect the other end of the ozone gas line to the bottom of the ozone outlet manifold and secure with tubing clamp SYSTEM STARTUP Restore power to the unit a...

Страница 6: ...m Below Keep for Your Records Installer _______________________________________________________________ System Purchased From ______________________________________________ Installation Date _____________________________ Serial Number _______________________________ ...

Страница 7: ...7 NOTES ...

Страница 8: ...CMP LLC 36 HERRING ROAD NEWNAN GA 30265 WWW C M P COM DEL 0621AB ...

Отзывы: