FIELD BUILT SUMP INSTALLATION:
h. Refer to TABLE 1 for flow rates
i. Minimum Pipe Depth (A) Side Port: 1-3/4in; Bottom Port: 4-3/4in
j. Ledge Width (B): 1-1/8in
k. Minimim Pipe Length
Before
Pipe Size Reduction:
8.5in
l. For additional information on proper drain installation refer to The Association of Pool & Spa Professionals ANSI/APSP/
ICC-7 2013 Standard and the Virginia Graeme Baker Pool & Spa Safety Act (VGB Act).
B
A
B
A
Flow P
ath Boundar
y
Flow P
ath Boundar
y
IMAGE 3 - FIELD BUILT SUMP DIMENSIONS
2. MAINTENANCE & INSPECTION
a. Covers/grates and all other SOFA components shall be replaced before the end of their service life. Service life begins
the month and year in which a SOFA component is installed with or without water. The cover/grate and screws should be
replaced at least every seven (7) years. Sump and frame service life is 30 years.
b. Inspect pool or spa regularly to ensure that the drain cover/grate is in place and secure.
c. Missing, broken, or cracked SOFA components shall be replaced before bathers are allowed to use the pool or spa. Loose
covers/grates shall be reattached before bathers are allowed to use the pool or spa.
d. If the cover is found with color changed, broken, cracked, missing, brittle components with chunks or pieces broken off, it
must be replaced. Do not use the pool/spa/facility until a replacement is made.
e. If there are stripped screw holes or if the brass insert receptacles are missing/removed, the SOFA must be replaced. Do
not use the pool/spa/facility until a repair or replacement is made.
f. If a drain cover/grate does not pass inspection:
• Close the pool or spa immediately
• Post a closure notice
• Keep the facility closed until a new drain cover and screws are properly installed.
3. WINTERIZING
• Requirements for winter will vary depending on region - follow normal winter and freeze protection practices for your
area.
• For areas that require partial drainage and/or clearing lines to prevent freeze damage:
• If your suction(s) have a dedicated suction line: Use a blower to clear the suction line of water and cap or close the
line with a valve to prevent freeze damage.
• If your suction(s) are connected to a skimmer/equalizer line: Follow skimmer winterization procedures. Optionally
blow and cap the suction line or fill line with foam rope/backer rod to protect from freeze damage.