![CMP 25207-7 Series Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/cmp/25207-7-series/25207-7-series_quick-start-manual_2627538003.webp)
3
A. SAFETY INSTRUCTIONS & PRECAUTIONS
When using two or more suction fittings on a common suction line, suctions must be separated by a minimum of 3
ft or they must be located on two different planes.
WARNING: DO NOT locate suction outlets on seating areas or on backrests for such seating areas.
Attention Installer: This manual contains important information about the installation, operation and safe use of this
product. Before installing this product, read and follow all warning notices and instructions which are included. This
information should be given to the owner and/or operator of this equipment.
To reduce the risk of drowning from hair and body entrapment, install suction fittings with a marked flow rate in
gallons per minute that exceeds the flow rate of your system by at least 25%. Always use multiple suction outlets. If
the fitting/cover breaks, is damaged, or is missing, shut the system down immediately. Do not use the system until
damaged parts have been replaced.
Keep hair and clothing a minimum of 12 inches from all suction fittings and drains at all times. Persons with long
hair should secure hair to a minimal length or wear swimming cap. Children should never be left unattended at any
time in a swimming pool, spa, or bathtub. Be sure the temperature of the water never exceeds the manufacturer’s
recommendations.
To reduce the risk of injury, installation and service should be done by a qualified Service Professional, certified
electrician or authorized CMP representative.
NOTE: In the event that one suction outlet is completely blocked, the remaining suction outlet(s) serving that system
MUST have a flow rating capable of the full flow of the pump(s) for the specific suction system.
Increasing size of the pump may increase flow rate of suction beyond rated safety limits causing entrapment or
death.
All Suction Outlet Fitting Assemblies (SOFAs) shall be installed in accordance with the manufacturer’s installation
instructions, or for Registered Design Professional SOFAs, in accordance with the registered design professional’s
engineering plans. Field modification made to a SOFA not authorized by the manufacturer’s installation instructions
shall void the SOFA certification.
Hair or body parts blocking the spa or pool suctions may become trapped and held against the suction fitting.
Entrapment against the suction fittings can result in drowning or other severe injury. Never sit on or lean up against
suction fittings. Never exceed the maximum allowable flow rate stated on the suction fitting. The suction fitting and
fasteners should be inspected for damage or tampering before use. Missing, broken, or cracked suction fittings shall
be replaced. Loose suction fittings shall be reattached or replaced before use of this facility.
The maximum hose length difference between any self-contained SOFA and the tee leading to the pump shall not
exceed 13 feet (3.96 m).
CMP drain covers are only certified for use with CMP sumps and frames. Do not mismatch with parts from other
manufacturers.
WARNING
WARNING
WARNING
WARNING
WARNING
NOTICE
NOTICE
NOTICE
NOTICE
NOTICE
NOTICE
NOTICE
SAVE THESE INSTRUCTIONS
When installing and using this equipment, basic safety precautions shall always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS.
READ, UNDERSTAND AND FOLLOW ALL WARNINGS AND INSTRUCTIONS.
ALWAYS PLUMB AND INSTALL ALL SUCTION FITTINGS ACCORDING TO ALL
BUILDING CODES THAT APPLY IN YOUR AREA.