4.6. Motor Calibration
4.6.1. Automatic Motor Calibration
■
To calibrate motors press the side button marked “Calibrate”.
■
On the calibration screen select a single motor or “All motors”.
■
Select “Automatic’” to start calibration.
4.6.2. Manual Motor Calibration
Manual motor calibration is used when working with lenses without physical scale stops such as
photo lenses. To manually calibrate a scale proceed as follows:
■
To calibrate motors press the side button marked “Calibrate”. On the calibration
screen select the motor you want to calibrate.
■
Select Manual.
■
Move the motor to the minimum scale limit using the side buttons. The left side
buttons control motor speed and the right side enables you to stop and reverse
direction.
■
When you have reached the desired minimum motor position press “set”.
■
Repeat the procedure for the maximum scale limit and press “set” again.