Installation
Water Connection
Continued on the next page.
CAUTION:
To prevent damage to the dishwasher supply valves, the installing
plumber must thoroughly flush debris from the water supply line before connecting
it to the dishwasher. Damage caused by improper installation is not covered by the
limited warranty.
HOT
WATER
Connect the plumbing in accordance with the specifications below.
NOTE:
All plumbing connections
MUST BE POSITIONED
to allow the machine to be
moved for service and cleaning.
INSTALL A 1/2" OR LARGER SHUT-OFF VALVE IN THE WATER SUPPLY
LINE AS CLOSE TO THE DISHWASHER AS POSSIBLE FOR SERVICING.
THE PRV SHIPPED INSIDE THE DISHWASHER MUST BE INSTALLED
IN THE INCOMING WATER LINE AFTER THE SERVICE SHUT-OFF VALVE.
THE PRV MUST BE ADJUSTED TO PROVIDE 20-22 PSI FLOWING
PRESSURE MEASURED AT THE DISHWASHER.
THE DISHWASHER IS EQUIPPED WITH A 6 FT / 1.8 m FLEXIBLE FILL
HOSE WITH A 3/4" FNPT FITTING.
WATER HARDNESS OF 3 GRAINS/US GAL - 0.83 IMP GAL - 5.3mg/L
OR LESS.
BOOSTER
RISE °F
BOOSTER
kW
MINIMUM INCOMING
TEMPERATURE
MIMIMUM INCOMING
SUPPLY FLOWING PRESSURE
MIMIMUM/MAXIMUM
OPERATING FLOWING PRESSURE
MINIMUM 1/2" NPT OR LARGER HOT WATER SUPPLY LINE.
20-22 PSI 138-152 kPa
45 PSI/310 kPa
45 PSI/310 kPa
110°F/ 43°C
70
°
RISE
6kW
40
°
RISE
4kW
140°F/ 60°C
20-22 PSI 138-152 kPa