background image

11-2016

181GW

Quick Setup 

Instructions

WARNING

: Electrical and plumbing  

connections need to be made by  
a qualified service person who will 
comply with all available Federal, State  
and Local Health, Electrical, Plumbing  
and Safety codes. 

 

6

STEP

Level dishmachine by adjusting leveling legs. 

Dishmachine must be level front and back. 

5

STEP

After filling dishwasher for the first time, 

(CAUTION: 

turn power supply off) reconnect the factory 

unplugged wire to booster high-limit switch located

behind front panel.

4

STEP

If necessary adjust the temperature by turning the 

adjustment stem clockwise to increase.

WASH TEMP 150°-160°

POWER

FINAL RISE TEMP 180°-195°

OFF                          ON

DRAIN                        

  FILL

START

CYCLE

CHEMICAL

PUMPS

POWER

DRAIN & FILL

CYCLE

THERMOSTAT

BOOSTER

HIGH LIMIT

SWITCH

5

4

RINSE 

PRESSURE 

GAUGE

LEVELING LEGS

6

NOTE:  To prevent Heating Element 
damage, the 181GW heater must be 
filled with water before the heating 
element is energized. For this reason
the High Liimit Switch has 
intentionally been disconnected at 
the factory and will require 
re-connection.

5

The Spirit of Excellence

an Ali Group Company

Отзывы: