After the luminaire has been securely mounted in the desired location, conduit which will contain the primary wiring must
be attached. A UL-Listed waterproof conduit and the appropriate conduit fittings must be used.
IMPORTANT: The UL-Listed rubber plugs installed in the ends of every luminaire are only to be removed if they are to be
replaced by the proper liquid tight conduit adaptor, or if another luminaire is to be coupled to an ajoining luminaire.
ATTACHING CONDUIT TO THE END OF THE
LUMINAIRE:
Remove one rubber plugs at the end of the luminaire, and
install a standard Liquid Tight fitting into the 7/8” hole at
the end of the luminaire.
Attach Liquid Tight conduit to the luminaire in one of
the following ways:
ATTACHING CONDUIT TO THE UNDERSIDE OF THE
LUMINAIRE:
If it is required that the conduit penetration location be
concealed, a standard 7/8" hole may be drilled in the back
of the luminaire (making sure the hole is drilled at least 6
inches away from the ballast or any internal parts or
wiring) and a standard liquid tight conduit connector may
be installed.
Remove the snap-fit cover and the two wiring compartment covers at each end of the luminaire.
Note: If only a single luminaire is being installed, only one wiring compartment cover need be removed.
Conduit
UL-Listed
liquid tight
conduit
and conduit
fitting.
7/8" hole
UL-Listed liquid tight
conduitand conduit fitting
Conduit
locknut
Snap-fit cover
wiring
compartment
Attaching conduit to the lumimaire
Page 3