Clover B14A Скачать руководство пользователя страница 9

9


 

The  ambient  temperature  is  high. 

It  is  normal  for  the  cooler  to  run 
continuously  at  high  ambient 
temperatures. 

There  has  been  a  substantial  loss  in 
the  sealed  system's  charge  of 
refrigerant. 

If  refrigerant  leak  is  suspected,  return 
cooler  to  authorized  service  center  or 
factory  for  repair. 

C.  The  cooler 
compressor  runs 
continuously,  but  I 
do  not  have  cold 
water. 

The  compressor  is  defective. 

Same  as  above. 

HOT  WATER  SYSTEM

 

If  cooler  equipped  with  hot  water 
switch  may  be  OFF. 

Turn  the  hot  water  switch  ON. 

There  is  a  loose  or  broken  wire 
connection  in  the  hot  water  system. 

Identify  the  loose  or  broken  wire 
connection,  repair  as  necessary. 

The  hot  control  is  defective. 

Replace  the  hot  control. 

The  heat  limiter  is  "ON". 

Push  "Reset"  button  of  heat  limiter. 

A.  The  hot  water  is 
not  hot. 

The  hot  tank  heater  is  defective. 

Replaced  the  hot  tank  heater  or  hot 
tank  assembly. 

Usage  of  the  hot  water  system  is 
greater  than  its  capacity. 

Inform  the  customer  of  the  hot  water 
system's  maximum  capacity. 

B.  The  hot  water  is 
hot,  but  not  hot 
enough. 

The  hot  control  is  defective. 

Replace  hot  control. 

Hot  water  flow  is  designed  to  flow 
slowly  than  cold  and  cook  water  to 
prevent  splashing. 

Advice  the  customer  of  this  safety 
feature. 

Defective  faucet. 

Replace  faucet. 

C.  The  hot  water 
flows  slowly  or  not 
at  all. 

Hot  tank  plugged  with  mineral  deposits.  De-lime  tank. 

D.  Hot  tank  is  noisy. 

The  hot  tank  heater  is  caked  with 
mineral  deposits. 

Slight  boiling  sound  normal  during 
heating  cycle.  De-lime  tank. 

NOISE

 

The  cooler  is  not  level. 

The  cooler  must  be  leveled. 
Place  the  cooler  on  even  surface. 

A  section  of  the  tubing  inside  the 
cooler  is  touching  other  parts  of  cooler, 
causing  noise  to  be  generated  due  to 
vibration. 

Adjust  position  of  the  tubing  to  make 
sure  it  is  not  in  contact  with  any  other 
parts. 

Check  the  connection  of  the  fixed 
screws. 

Completely  connect  the  fixed  screws. 

A.  There  is 
excessive  noise 
coming  from  the 
cooler,  but  it  is 
otherwise  operating 
normally. 

The  compressor's  operation  is  noisy 
because  of  inherent  conditions. 

Advise  the  customer  of  the  cooler's 
normal  operating  sounds. 

WATER  LEAKAGE

 

A.  Water  drips  from 
faucet. 

The  faucet  body  packing  and  spring  is 
defective. 

Press  down  the  faucet  lever  several 
times.   
Replace  faucet  assembly. 

Содержание B14A

Страница 1: ...1...

Страница 2: ...NTS 5 4 INSTALLATION PROCEDURES 5 6 5 STORAGE 6 6 CLEANING 6 7 7 TROUBLESHOOTING GUIDE 7 8 8 WIRING DIAGRAM 9 9 EXPLODED VIEW SERVICE PARTS LIST A B14A 10 11 B B14B 12 13 FOR YOUR SAFETY Please read t...

Страница 3: ...cycle is out of order contact nearest authorized service center for maintenance repair and adjustment 1 SPECIFICATION PARTS IDENTIFICATION MODEL B14A HOT COLD B14B COOK COLD DIMENSION 313W 323D 963H m...

Страница 4: ...4 2 OPERATION FUNCTION OF PARTS...

Страница 5: ...en turn into the liquid refrigerants of low temperature and low pressure conditions by passing through the capillary tubes The liquid refrigerant of low temperature low pressure absorbs the surroundin...

Страница 6: ...e supplied water from cold water hot water or room temperature water respectively Hot tank heater Heats the supplied room temperature water to hot water Hot control Controls the temperature of hot wat...

Страница 7: ...MAY SCALD 5 STORAGE A Switch off hot water switch Unplug power cord B Drain hot water by opening faucet Then do the same on cold water faucet C Place a bucket behind the drain pipe By unscrewing the...

Страница 8: ...OUBLESHOOTING GUIDE TROUBLE POSSIBLE CAUSE REMEDY REFRIGERATION SYSTEM No electric power to outlet Turn on electric power outlet The thermostat is misadjusted or defective Adjust or replace the thermo...

Страница 9: ...not hot enough The hot control is defective Replace hot control Hot water flow is designed to flow slowly than cold and cook water to prevent splashing Advice the customer of this safety feature Defec...

Страница 10: ...large draw or series of draws and reservoir has not yet refilled Non Spill System only Wait until the cold water tank is filled with water after a large draw due to inherent restriction of the Non Spi...

Страница 11: ...11...

Страница 12: ...12...

Страница 13: ...13...

Страница 14: ...14...

Страница 15: ...15...