Clover B14A Скачать руководство пользователя страница 8

8


E.

 

Wash  the  faucets,  drip  tray  with  mild  soap  and  water.  Then,  rinse  them  with  clean  water 
immediately. 

F.

 

Cleanse  interior  of  cold  water  tank  with  a  clean  dish  towel. 
Do  not  use  bleach  or  any  cleaning  agents  containing  bleach  or  chlorine. 

G.

 

Assemble  drip  tray,  grid,  faucets  and  baffle. 

H.

 

Pour  clean  water  into  cold  water  tank  and  open  cold  faucet  to  flush  the  entire  water  trail.  Repeat 
this  step  at  least  three  times.  Then,  close  the  faucet. 

Steps  I,  J  are  for  Hot  &  Cold  model  only. 
I.

 

Open  hot  water  faucet.  Then,  until  the  water  flow  from  hot  water  faucet  is  continuous  and  clear, 
pour  clean  water  into  cold  water  tank.  Then,  close  the  faucet. 

J.

 

Open  drain  cap  to  flush  water  trail  in  hot  water  tank. 
Repeat  this  step  at  least  three  times  and  close  the  drain  cap  at  the  end. 

K.

 

Brush  out  and  vacuum  the  dirt  and  dust  from  condenser.  Do  not  use  abrasive  or  wire  brush. 

L.

 

Follow  Installation  Procedures  to  operate  the  cooler.

 

 

7.  TROUBLESHOOTING  GUIDE 

TROUBLE 

POSSIBLE  CAUSE 

REMEDY 

REFRIGERATION  SYSTEM

 

No  electric  power  to  outlet. 

Turn  on  electric  power  outlet. 

The  thermostat  is  misadjusted  or 
defective. 

Adjust  or  replace  the  thermostat,  as 
necessary. 

The  wires  leading  to  the  thermostat  are 
defective  or  are  not  connected. 

Check  the  internal  wiring. 
Make  repairs  as  necessary. 

The  line  voltage  is  low. 

Check  the  line  voltage.  It  must  be  at 
least  90%  of  minimum  voltage. 

The  compressor  over-load 
Protector  (OLP)  is  defective. 

Replace  the  defective  over-load 
protector. 

The  starting  relay  (PTC)  is  defective. 

Replace  the  starting  relay. 

A.  Compressor  does 
not  run. 

The  compressor  is  defective. 

Replace  the  compressor. 
Return  cooler  to  authorized  service 
center  or  factory  for  repair. 

Poor  ventilation. 

Minimum  side  &  rear  clearance  4" 

The  condenser  is  dirty  or  restricted. 

Clean  the  condenser  or  relocate  the 
unit  to  prevent  restricting  the 
condenser. 

B.  Water  is 
adequately  chilled, 
but  cooler  runs 
excessively  or 
continuously. 

The  thermostat  is  defective.  (the 
contacts  are  shorted  or  the  control  is 
not  adjusted  properly) 

Replace  or  adjust  the  thermostat  as 
necessary. 

Содержание B14A

Страница 1: ...1...

Страница 2: ...NTS 5 4 INSTALLATION PROCEDURES 5 6 5 STORAGE 6 6 CLEANING 6 7 7 TROUBLESHOOTING GUIDE 7 8 8 WIRING DIAGRAM 9 9 EXPLODED VIEW SERVICE PARTS LIST A B14A 10 11 B B14B 12 13 FOR YOUR SAFETY Please read t...

Страница 3: ...cycle is out of order contact nearest authorized service center for maintenance repair and adjustment 1 SPECIFICATION PARTS IDENTIFICATION MODEL B14A HOT COLD B14B COOK COLD DIMENSION 313W 323D 963H m...

Страница 4: ...4 2 OPERATION FUNCTION OF PARTS...

Страница 5: ...en turn into the liquid refrigerants of low temperature and low pressure conditions by passing through the capillary tubes The liquid refrigerant of low temperature low pressure absorbs the surroundin...

Страница 6: ...e supplied water from cold water hot water or room temperature water respectively Hot tank heater Heats the supplied room temperature water to hot water Hot control Controls the temperature of hot wat...

Страница 7: ...MAY SCALD 5 STORAGE A Switch off hot water switch Unplug power cord B Drain hot water by opening faucet Then do the same on cold water faucet C Place a bucket behind the drain pipe By unscrewing the...

Страница 8: ...OUBLESHOOTING GUIDE TROUBLE POSSIBLE CAUSE REMEDY REFRIGERATION SYSTEM No electric power to outlet Turn on electric power outlet The thermostat is misadjusted or defective Adjust or replace the thermo...

Страница 9: ...not hot enough The hot control is defective Replace hot control Hot water flow is designed to flow slowly than cold and cook water to prevent splashing Advice the customer of this safety feature Defec...

Страница 10: ...large draw or series of draws and reservoir has not yet refilled Non Spill System only Wait until the cold water tank is filled with water after a large draw due to inherent restriction of the Non Spi...