background image

USER MANUAL : 

 

DOCUMENT NAME

Activating this function will launch the Bluetooth Server which will search for the available remote devices in the immediate 

vicinity. 

Once the search has been completed, a list of the available devices will be displayed. Should the device you are looking for,
not appear in the list, press the 'Refresh' button to start the search again. Please remember that battery operated devices 

will need the Bluetooth interface activated before it will be found by the Bluetooth Server. This is normally done by giving 
the  onboard  pushbutton  a  short  press and  releasing.  Th
waiting for a connection. 

On some of the legacy  equipment you might see an entry that has no listed Device Code. This is because the Bluetooth 
interface  'Friendly  Name'  needs  to  be  updated  before  it  is  correctly  recognised. 

screen  once  you  are  connected

.  This  entry  is  a  valid

expecting listed as an option.  
To make a connection, select the device from the list and
device in the list will initiate a connection immediately.

MANUAL : CDS541 CUMULUS PULSE LOGGER 

NAME 

CLASSIFICATION 

DATE 

PAGE

the Bluetooth Server which will search for the available remote devices in the immediate 

 

 

Once the search has been completed, a list of the available devices will be displayed. Should the device you are looking for,

the 'Refresh' button to start the search again. Please remember that battery operated devices 

will need the Bluetooth interface activated before it will be found by the Bluetooth Server. This is normally done by giving 

s  and  releasing.  The  blue  LED  will  flash  to  indicate  that  the  interface  is  active  and 

 

 

On some of the legacy equipment you might see an entry that has no listed Device Code. This is because the Bluetooth 

'  needs  to  be  updated  before  it  is  correctly  recognised. 

This  can  be  done  in  the  configuration 

entry  is  a  valid  device  and  can  be  selected  if  you  cannot  see  the  device  you  are 

connection, select the device from the list and press the 'Connect' button. Alternatively, double clicking on the 

device in the list will initiate a connection immediately.  

 

 

PAGE 

the Bluetooth Server which will search for the available remote devices in the immediate 

Once the search has been completed, a list of the available devices will be displayed. Should the device you are looking for, 

the 'Refresh' button to start the search again. Please remember that battery operated devices 

will need the Bluetooth interface activated before it will be found by the Bluetooth Server. This is normally done by giving 

te  that  the  interface  is  active  and 

On some of the legacy equipment you might see an entry that has no listed Device Code. This is because the Bluetooth 

This  can  be  done  in  the  configuration 

if  you  cannot  see  the  device  you  are 

the 'Connect' button. Alternatively, double clicking on the 

Содержание CDS541

Страница 1: ...se Logger User Manual User 28 February 2018 V2 0 Draft Confidential CDS541 Cumulus Pulse Logger User Manual docx This document contains information relating to the rights of Cape Digital Solutions The...

Страница 2: ...021 MANUAL CDS541 CUMULUS PULSE LOGGER NAME CLASSIFICATION DATE PAGE AMENDMENT HISTORY Amendment Details Amended By Compile document Alex Romanov Updated modem technology specs Alex Romanov New config...

Страница 3: ...0mA loop input and 24V loop power generator 1 8 5 Using the Pulse Input with echo output 1 8 6 Using the ECO interface 2 Logger Setup 2 1 Setup via Bluetooth Configure 2 2 Setup via Remote Configure 2...

Страница 4: ...r easy installation and setup without the need for a complicated server infrastructure Setup and management software CloudWorks is supplied free of charge to allow clients to manage their own networks...

Страница 5: ...of 30mA allowing for the powering of an external piece of equipment or current loop device eliminating the need option will also function under battery operation 2 x Pulse inputs with echo output Puls...

Страница 6: ...NAME CLASSIFICATION DATE PAGE or Bluetooth Interface Central Processor GPS Satellite Receiver Input Output Interface 3 x Alkaline Batteries External 12V Power Supply Power Management 2 wire Isolated 4...

Страница 7: ...usly connected to the server allowing for the streaming Cumulus Pulse logger uses standard D Cell alkaline batteries that will last several years In this mode the logger will wakeup adjustable normall...

Страница 8: ...und 13 Pulse 2 input 14 Ground for Pulse 2 input 15 Ground for Pulse 2 output pulse splitter output 16 Pulse 2 pulse splitter output switch to ground 17 Digital input 18 Ground for digital input 19 EC...

Страница 9: ...also populating the logger with alkaline batteries means that the logger can be put e is solar power available the logger will remain online with the server Should the solar power fail the logger wil...

Страница 10: ...igned to connect to a volt free mechanical or electronic switch The logger has Example for connecting to a volt free contact Example for connecting to an Open Collector electronic switch note that pin...

Страница 11: ...has been designed to supply a maximum of 30mA Please note using the 24V power generator to power a loop device uses a substantial amo he loop should only be powered each time the device needs to be re...

Страница 12: ...nfiguration of MANUAL CDS541 CUMULUS PULSE LOGGER NAME CLASSIFICATION DATE PAGE Example configuration of water meter with electronic interface Please note the polarity of the interface Ground connecti...

Страница 13: ...umulus Pulse logger has an onboard Bluetooth interface which allows for the device There are two different places in the software to activate the Bluetooth connection The first option is from the log...

Страница 14: ...r the Refresh button to start the search again Please remember that battery operated devices will need the Bluetooth interface activated before it will be found by the Bluetooth Server This is normall...

Страница 15: ...Firstly it will stream diagnostic information is operating This will be information like the GSM signal strength next wakeup time is initiating a connection to the server ommand Mode which allows the...

Страница 16: ...ed into Command Mode and the current setup data retrieved and displayed on the right hand screen nt to the device only after the parameter setup field has been left What this means is that while adjus...

Страница 17: ...an be cleared by right clicking in this box and before any of the settings changes or other instructions are accepted command in Diagnostic Mode will cause the logger to switch to Command Mode but tha...

Страница 18: ...attery or Mains Digital input status 20mA loop current reading in milliamps 20mA current loop reading with its calibration data implemented including the unit The I O Parameter block is the data used...

Страница 19: ...pulate the database that is associated with a specific logger Each database and Vendor Code assigned to it Data is matched between these systems using that code This code is also used to separate comm...

Страница 20: ...number is normally not required as your network will default this value This can be customised using the SMS Serv Centre field If you are using a foreign simcard on a network the logger will need to b...

Страница 21: ...gle chance to wake up fails it will return to sleep and a only reconnect at the next wakeup period At the start of a wake up the Max Start Time timer will be started Should the connection to the serve...

Страница 22: ...V 30mA power generator The Cumulus Pulse Logger can generate a stable 24V allowing for the powering of an external piece of equipment or current loop device the need for a secondary power supply This...

Страница 23: ...for a couple of minutes typically 5 minutes set in the server software in order to get a fix If this takes too long the remote device will be put back to sleep without updating the position This is do...

Страница 24: ...ent Upgrading firmware on the logger can be done through the Bluetooth interface Newer versions of the software for each into the Cloudworks software so will not need an internet connection to collect...

Страница 25: ...is complete the following message will be displayed Please power cycle the logger and then reconnect the Bluetooth interface if you wish to carry out further configurations when a logger is in battery...

Страница 26: ...when you configure via the Bluetooth setup option Again d commands are sent to the device only after the parameter setup field has been left What this means is that while adjusting a parameter in its...

Страница 27: ...enting you from making any further changes The Remote Configure screen has one further tool available in its arsenal and that is the Send Test SMS function The purpose of this function is to not only...

Страница 28: ...n which are picked up As you can see the parameters are the same as when you configure via the Bluetooth setup option with one or two minor All the parameter fields are empty at this point To create a...

Страница 29: ...ts that are still present in the database Each command has associated with it a status those that still need to be executed Listed also is the response to each command for diagnostic purposes You can...

Отзывы: