Cloudray MYJG-50 Скачать руководство пользователя страница 6

Power Supply MYJG-50 User Manual

www.cloudraylaser.com

6

Supply Does

not work

3. Fuse is burned.

No laser emission when

manual test.

Contact with us for

repair.

AC power on
but no laser
emission

1. Control wire

connected wrong

Check if wire is connected

correctly according to

Operation

Instruction

Rewiring correctly

2. Internal

connector is loose.

Open outside case and

check

Tighten connector.

3. Protection switch

on but on water

through or water

through switch is

broken.

Voltage>0.5V

between

“WP”and”G”

Water through or

change

water

through switch.

4. Wrong output
laser signal

Voltage between”TH ”

and “G” should<3V when

When

laser-open

controlled by high level

Replace CNC card or

change GND.

Voltage between"TL" and

“G”

should>3V

when

laser-open controlled by

low level.

5. Power

control

signal is 0.

Voltage between “IN”and

“G” is 0.

Increase

voltage

between “IN”and “G”.

6. Fuse is burned.

Fan does not work

Send back factory for

maintenance

7. Others

Send back factory for

maintenance

Laser
emission at
all times

1.When “TL” control

laser: short circuit

between”TL

”and

“G”.

Voltage between”TL ”

and “G” =0

disconnected

between”TL

”and

“G”.

2. Circuit is broken.

Send back factory for

maintenance

3. Switch of manual

test laser emission is

broken.

Change switch of

manual test laser

emission.

4. Other causes.

Send back factory for

maintenance

Current is

not
increased

1. AC voltage is too

low

Output current is always at

5mA around.

Use

AC

voltage

regulator.

Send back factory for

maintenance

2. Power

supply

and laser Device is

not connected very

well

3. Power control

signal from CNC

card

is

not

connected very well

with “IN”.

Output current is always at

10mA around.

Re-connected

3. Potentiometer of

power is broken.

Output current is not

stable.

Change

potentiometer.

4. PWM frequency

or amplitude is not

suitable.

Change

PWM

frequency

or

amplitude.

www.cloudraylaser.com

www.cloudraylaser.com

www.cloudraylaser.com

www.cloudraylaser.com

www.cloudraylaser.com

www.cloudraylaser.com

www.cloudraylaser.com

www.cloudraylaser.com

www.cloudraylaser.com

Содержание MYJG-50

Страница 1: ...r power supply prolong the laser tube s service life 4 Test Mode One button to test the output laser manually 50 Max Power 5 Application Sculpture and cut acrylic fabric double color sheet rubber etc...

Страница 2: ...ak value 5V Check and make sure protection switch WP connection is correct at same time 3 Voltage of Power Input MYJG 50W s power input of the power supply shall be 220VAC 50Hz This power supply can b...

Страница 3: ...ly and Controller w w w c l o u d r a y l a s e r c o m w w w c l o u d r a y l a s e r c o m w w w c l o u d r a y l a s e r c o m w w w c l o u d r a y l a s e r c o m w w w c l o u d r a y l a s e...

Страница 4: ...0 5 or PWM Output laser Pmin Pmax Low 0 3V Unconnected Output about 40 laser Low 0 3V Any value ok No laser Any value ok Any value ok High 3V No laser VI The connection of power supply and control bo...

Страница 5: ...rcuit between AC and AC Rewiring and avoid short circuit 3 Internal Wiring Short circuit between AC and AC or AC and FG Send back factory for maintenance 4 Other Causes AC Power On but Fan of Power 1...

Страница 6: ...emission at all times 1 When TL control laser short circuit between TL and G Voltage between TL and G 0 disconnected between TL and G 2 Circuit is broken Send back factory for maintenance 3 Switch of...

Страница 7: ...card enclosure of power supply with enclosure of laser machine Laser emission is not stable during working When two laser head works action abnormal w w w c l o u d r a y l a s e r c o m w w w c l o...

Отзывы: