6.3 Microphone Level Controls

Each microphone has separate front panel
mounted controls for their respective level.
Rotating any microphone level control fully
anti-clockwise effectively turns the
microphone off. In addition microphones can
be muted via the access contacts on the rear
panel (see section 6.1)

Master microphone level can be controlled
locally via the front panel rotary control, or
through a remote wall plate up to 100m away
from the unit.  To configure the CX462 for
remote level operation, the front panel switch
must be in the 'REMOTE' position.
The rear panel switch marked 'REMOTE
TYPE' should be in the 'ANALOGUE' position.
Master microphone level can also be
controlled via the Cloud CDI-S100 Serial
Interface Module (see section 8.2).

6.4 Microphone Equalisation

Two-band equalisation is provided for each individual microphone input. The pre-set controls
to adjust the equalisation are located to the upper-right of each front panel microphone level
control.  The characteristics of the equalisation are optimised for the tonal correction of
speech signals. The HF control provides ±10dB at 5kHz whilst the LF control provides ±10dB
at 150Hz.

A parametric equaliser is applied to all the microphone signals, to allow the installer to correct
for microphone or room resonance.  The pre-set controls to adjust the equalisation are
located to the upper-right of the microphone master level control (front panel).  This equaliser
has been optimised for vocals and provides a gain of ±10dB over a frequency range of
300Hz - 3kHz.

All microphone equalisation controls are concealed behind the removable front panel. To
effectively bypass an equalisation section, the gain control should be set to 0dB (mid-
position/vertical).

6.5 High Pass Filter

All microphone channels pass through a high pass filter operating at 150Hz with a slope of
18dB per octave; as such it provides effective attenuation of breath blasts and LF handling
noises.  This filter can be switched in or out via the front-panel switch located to the right of
the microphone master level control.  This switch will be concealed when the removable front
panel is in place.

STANDARD WIRING CONVENTION
USE TWO CORE SCREENED CABLE

FRONT PANEL SWITCH SHOULD BE
SET TO THE ‘REMOTE’ POSITION

REAR PANEL SWITCH SHOULD BE
SET TO THE ‘ANALOGUE’ POSITION

REMOTE CONTROL OF MIC LEVEL

FRONT SWITCH

REMOTE (IN)

REAR SWITCH

ANALOGUE (OUT)

1

2

3

3 POLE

CONNECTOR

1

2

3

RL-1

Содержание CX462

Страница 1: ...CX462 Installation Setup Guide Version 3 CX462 AUDIO SYSTEM CONTROLLER Cloud Electronics Limited Copyright Cloud Electronics Limited 2004 Clearly Better Sound...

Страница 2: ......

Страница 3: ...CS LIMITED CX462 Installation and Setup Guide Cloud Electronics Limited 140 Staniforth Road Sheffield S9 3HF England Phone 44 0 114 244 7051 Fax 44 0 114 242 5462 E mail technical cloud co uk WebSite...

Страница 4: ......

Страница 5: ...tion 4 5 4 Line 6 Priority 4 6 Microphone Inputs 5 6 1 Microphone Access Contacts 6 6 2 Microphone Gain Controls 6 6 3 Microphone Level Controls 7 6 4 Microphone Equalisation 7 6 5 High Pass Filter 7...

Страница 6: ...m Controller Setup And Installation Guide 12 Troubleshooting 13 12 1 Ground Earth Loops 13 12 2 Connecting balanced signals to unbalanced line inputs 13 12 3 Cloud CDI S100 Serial interface is not wor...

Страница 7: ...one inputs that are mixed and sent to the separate mono mic output In order to increase the mixers versatility there are controls to add the output of one section to the other There are various option...

Страница 8: ...u 1 5V The pre set gain controls should be set so that all the input signals operate at the same level within the CX462 and the music level controls have an optimum control range GAIN LINE 1 LINE 2 LI...

Страница 9: ...PE should be set to the ANALOGUE position Jumpers J7 J10 determine whether the control of the music controls is determined by the rear panel switch A table containing the possible configurations and t...

Страница 10: ...Low Frequency A flat frequency response can be achieved by positioning the slots on the control shafts in the vertical plane the HF control has a range of 10dB at 10kHz and the LF control has a range...

Страница 11: ...ers from the list below to the ON position NOTE Microphones one and two have their jumpers located on the upper microphone input circuit board When setting the jumper s please ensure that you w Remove...

Страница 12: ...ault factory configuration of these jumpers is to bypass access terminals leaving all microphone inputs active It is also possible to mute the microphone inputs using the CDI S100 interface module In...

Страница 13: ...speech signals The HF control provides 10dB at 5kHz whilst the LF control provides 10dB at 150Hz A parametric equaliser is applied to all the microphone signals to allow the installer to correct for m...

Страница 14: ...after the Add Mic front panel rotary control by setting internal jumper J15 to PRE or POST If the priority circuitry is set before this control PRE then the music signals will attenuate regardless of...

Страница 15: ...of the CX462 can operate in either stereo or mono mode The default setting is for the CX462 to operate in stereo mode In mono mode all stereo signal sources are mixed internally and output the same s...

Страница 16: ...ed to either CON3 or CON4 depending on the output socket you choose to use Installation 1 Switch off the mains supply and remove the CX462 s power lead 2 Remove the unit s top panel 3 Fit the EQ modul...

Страница 17: ...o interface module is installed 4 Locate connector CON7 16 pin ribbon 5 Remove M3 screw behind CON7 and M3 screw left of C96 Keep to one side 6 Screw 25mm hex spacers into screw holes in step 5 7 Conn...

Страница 18: ...Alarm condition when the relay opens w N O Alarm condition when the relay closes When setting the jumper s please ensure that you Remove the mains cable from the rear of the product before removing th...

Страница 19: ...event a noisy loop see diagrams below 12 2 Connecting balanced signals to unbalanced line inputs We recommend the use of a transformer to convert a balanced signal to an unbalanced signal suitable for...

Страница 20: ...OTE position w The rear panel switch marked REMOTE TYPE should be in the DIGITAL position If the module is still not working correctly once these aspects of the CX462 unit have been configured consult...

Страница 21: ...contacts for all four microphone inputs so that when the product arrives all inputs will be enabled Internal jumpers J1 to J4 bypass access contacts for microphones 1 to 4 respectively To enable acce...

Страница 22: ...e symbol while power is supplied to the unit Terminals to which the hazardous live symbol refers require installation by a qualified person CAUTION Mains Fuse Replace the mains fuse only with the same...

Страница 23: ...Notes...

Отзывы: