Clou CL7206B2 Скачать руководство пользователя страница 1

 

  1 / 52 

 

 

 

 

 

 

 

 

 

User Manual of 

CL7206B2 RFID Reader 

 

 

 

 

 

 

 

Shenzhen Clou IOT Technologies Co., Ltd 

(V2.0.2) 

Содержание CL7206B2

Страница 1: ...1 52 User Manual of CL7206B2 RFID Reader Shenzhen Clou IOT Technologies Co Ltd V2 0 2...

Страница 2: ...2 52 Welcome to be user of CLOU RFID products Thanks for choosing CLOU s integrated RFID Reader CL7206B2 We believe our device will bring convenience for your work...

Страница 3: ...9 2 3 2 I O aviation port chart 10 2 3 3 LED panel description 11 2 4 External cable connection description 12 2 4 1 Power supply communication cable description 12 2 4 2 I O control interface cable d...

Страница 4: ...er performance 20 4 Software operating 21 4 1 Demo software 21 4 2 Application environment 21 4 3 Software version 21 4 4 Installation 21 4 5 Operation 22 4 5 1 Device connection 22 4 5 2 Data display...

Страница 5: ...I O configuration 41 4 5 14 Others 42 4 5 15 Tools 44 5 Common failures 47 5 1 Daily maintenance 47 5 2 Common failure analysis and solution 47 6 Package 49 6 1 Package 49 6 2 Accessories 49 6 3 Stora...

Страница 6: ...ity strong anti interference etc 1 2 Technical 1 2 1 Main function Protocol support ISO18000 6C 6B standard Built in LINUX operating system Multiple communication port Ethernet RS232 RS485 USB Wi Fi B...

Страница 7: ...ntegrated circular antenna gain 9dBi RS232 serial communication rate 115200bps default 19200 bps 9600bps RS485 interface communication rate 115200bps default 19200 bps 9600bps Support Weigand 26 34 66...

Страница 8: ...on Physical size 290mm 290mm 115mm accessories not included Image 2 1 Structure diagram 2 2 Weight Main body 5kg accessories excluded 2 3 Interface chart Image2 2 I O communication interface 1 power c...

Страница 9: ...ation port aviation port number chart Aviation plug signal definitions Chart 2 1 Power communication interface signal definition PIN Description PIN definition 1 Power supply GND PGND 2 Power supply G...

Страница 10: ...13 Ethernet port RD 14 RS232 receiving RXD TX Picture2 4 I O interface aviation port number chart 2 3 2 I O aviation port chart I O aviation port definition as per in chart 2 2 Chart 2 2 I O port sign...

Страница 11: ...ocoupler 1 external signal input anode IN1 6 Optocoupler 2 external signal input anode IN2 7 Optocoupler external signal input cathode IGND 8 Wiegand output 0 WG0 9 Wiegand output 1 WG1 10 GND AGND 11...

Страница 12: ...al cable connection description 2 4 1 Power supply communication cable description Cable Specifications Black insulated skin with metal screening net 14 shares inner core outer diameter 7 8mm main cab...

Страница 13: ...is 2 5m aviation plug is connected with reader I O control interface 14 core lines mainly provides two way optical coupling input port two way relay control ports two Wiegand output two way communicat...

Страница 14: ...PIN description PIN Color Marking number 1 Relay 1 output port White 6 2 Relay 1 output port Blue 8 3 Relay 2 output port White black 7 4 Relay 2 output port Blue black 9 5 Optocoupler 1 external sign...

Страница 15: ...e length within 5meters impedance 50 the insertion loss less than 2dB Of course you can choose a high performance cable appropriately increase the length but keep the insertion loss less than 2dB Note...

Страница 16: ...al size 10 2 x 10 2 x 1 32 Antenna Connection coax pigtail Rev INC Males Working temperature 25 70 Lightning protection DC grounded Environmental rating IP65 2 4 4 Network connection chart Ethernet co...

Страница 17: ...e network cable and serial cable type selection and length restrictions 4 When installing multiple readers pay attention to reader antenna display way the minimum distance between the antennas avoid t...

Страница 18: ...ding performance reaches its best after testing 3 3 2 Connected with PC RS 232 interface is used for short range communication less than 10m can be connected to a PC via the serial port connector for...

Страница 19: ...per illustrated in picture 5 2 Note This installation method is suitable for 50mm 100mm diameter vertical pole Picture 3 2 Vertical pole installation 3 5 2 Horizontal pole installation 1 Align the Al...

Страница 20: ...hod is suitable for 50mm 100mm diameter horizontal pole Picture 3 3 Horizontal pole installation 3 6 Acceptance 3 6 1 Check physical installation 1 Check ensure the reader is fixed safely 2 Check ensu...

Страница 21: ...e reader and writer start up hear drop buzzer sound 4 2 Application environment The software environment Windows 2000 Service Pack 3 Windows Server 2003 Windows XP Service Pack 2 Windows 7 system The...

Страница 22: ...e gray means reader is not connected in the connecting reader option list select communication mode serial connection connection parameters select COM choose PC serial number communication baud rate s...

Страница 23: ...directly Select the communication mode TCP connection in the connect reader option list connect parameter input reader IP default 192 168 1 116 enter the communication port number default 9090 and cl...

Страница 24: ...ed Use the Ping command to test whether the network is connected on PC image 4 9 reader configuration 4 5 1 3 RS485 communication connection Select the communication mode in the connect to the reader...

Страница 25: ...elect the communication mode serial port in the connect reader option list connect parameter select COM the USB serial number detected by PC the communication rate is selected 115200 the default value...

Страница 26: ...an be read and write Reserve Data reserved area data store the password data etc Total Count total number of tags ANT1 the reading times of external antenna ANT2 the reading times of built in antenna...

Страница 27: ...e TID data of the custom length please refer to chapter 4 5 2 3 custom read 4 5 2 3 Custom read Click the button pop up dialog box as shown in Image 4 13 Select 6C tag configuration Matching read you...

Страница 28: ...tom configurations Select the 6B tag configuration and pop up dialog box as shown in image 4 14 Can choose to read TID data or user data Can matching read TID data Tip Customer who not familiar with t...

Страница 29: ...manual 29 Image 4 14 6B Tag custom configurations 4 5 2 4 Stop read Click button stop all read and write operations 4 5 3 Write data 4 5 3 1 Write EPC data Click button and pop up dialog box as shown...

Страница 30: ...ual 30 Image 4 15 write EPC data Select a label data contains TID information has been read fill in the EPC data 16 hex string click OK 4 5 3 2 Write user data Click button and pop up dialog box as sh...

Страница 31: ...l 31 Image 4 16 write user data Select a label data contains TID information has been read fill in the user data 16 hex string click OK 4 5 3 3 Custom tag action Click button and pop up dialog box as...

Страница 32: ...d 2 Click the custom operation button 3 Take detailed action to write lock destroy tag according to the reader protocol 4 5 4 TCP server client mode Select configuration on the main demo interface rea...

Страница 33: ...a server mode the connection is initiated by PC when the reader set as a client mode it will connect to the PC side automatically 4 5 5 Antenna configuration Select configuration on the DEMO main int...

Страница 34: ...K means configure succeeds If the antenna enable is not selected when select the corresponding reader on the DEMO main interface will pop up dialogue box as shown in image 4 20 Image 4 20 Antenna sele...

Страница 35: ...PC base band rate provides five options Tair 25us FM0 LHF 40KHz dense reading mode Tair 25us Miller4 LHF 300KHz fast reading mode 255 OUTO Session four choices 0 1 2 3 Q values provide sixteen options...

Страница 36: ...ion of the success of the dialog box click OK to complete power configuration 4 5 8 Clock setting Select configuration on the DEMO main interface senior reader configuration then pop up dialog box as...

Страница 37: ...ency hopping management dialog box as shown in image 4 24 Imag 4 24 Frequency Hopping management Select CMII 920 925MHz see Image 4 25 in the working band drop down list click the Settings select sing...

Страница 38: ...red Image 4 25 Frequency Band selection Note The purpose of setting up the automatic is to avoid the interference of the external signal and select the fast frequency hopping The default configuration...

Страница 39: ...complete collection of rfid tags data CL7206C4 support tag data caching mechanism and breakpoint resume in case that the tag s data loss because of the communication interrupted or PC application err...

Страница 40: ...resume mode PC will confirm to each tag data from reader under mass quantity of tag data will reduce the communication efficiency increase the system load we suggest When start the breakpoint upload f...

Страница 41: ...er a period of idle state to save power consumption the reader re enter the card reader automatically after idle time 4 5 13 GPI O configuration GPI O control is to provide the query and set up the I...

Страница 42: ...n the start condition is satisfied the reader will perform the configuration of the reader writer command GPO configuration Select configuration on the main interface GPI O configuration GPO configura...

Страница 43: ...Parameter configuration includes Weigand 26 Weigand 34 and Weigand 66 models Weigand 26 TID or EPC data reported from the end of the Weigand port is valid for 3 bytes Weigand 34 TID or EPC data repor...

Страница 44: ...the reader will be restored to the factory setting 4 5 15 Tools Data export Select tools on the main interface data export form XLS in the pop up dialog box as shown in image 4 32 select the required...

Страница 45: ...tions Select tools on the main interface software upgrade software the pop up dialog box as shown in image 4 33 Image 4 33 Application software upgrade To find the Bin upgrade file path in the upgrade...

Страница 46: ...CL7206B2 user manual 46 Image 4 34 Software upgrade successfully The process of the application of the base band software is the same as that of the application software...

Страница 47: ...indicator light failed when power on Check whether the communication is normal please contact customer service if it s not normal The serial port unable to connect Check if the serial cable is not co...

Страница 48: ...correct Check if the label is damaged Check if the label is placed in the reader s valid reading and writing range Check if the electromagnetic interference between the reader and the other device Fo...

Страница 49: ...box and the packing material should be kept properly after unpack Besides of the device in the box accessories equipped with the reader are also included in please check the product packing list to c...

Страница 50: ...20351000000551 1 Pcs Included 3 Power adapter 24V 2 5A 20109000000324 1 Pcs Included 4 AC power cable 20350000000195 1 Pcs Included 5 Network cable 20350000000188 1 Pcs Included 6 RS232 connection ca...

Страница 51: ...position and design of circuits without given notifications Thus the real product may be not in accordance with this manual Generally we will provide timely amendments to this manual If it s not provi...

Страница 52: ...ach device please keep it to enjoy the service 1 Products can replace free under conditions within one month after sale in the precondition of normal operation without repairing 2 Free maintenance won...