Ignition control
The ignition control monitors the welding start for five seconds. If
there is no welding signal within five seconds after start of welding,
the error message "Err.24 Arc failure ignition phase" will appear.
When the ignition control is off, wire feed will continue in case of a trou-
ble signal.
The monitoring is configured as follows:
Function
Description
Off
Reset on Start
Reset of error message is effected at the next signal
"Welding start“.
Reset from ex-
ternal
Reset of error message is effected by an external sig-
nal (OMI or bus system).