Installation 

1.  If  rack  mounting,  fit  the  mixer  to  the  rack  before  commencing  with  the 

rest of the set-up. 

2.  Connect 15 V DC power supply provided to the 2.1mm DC connector on 

the rear panel. 

3.  Turn the mixer on using the Power switch on the front panel. 

Basic Set-up for Microphones 

1.  Connect a microphone to any input channel. 

2.  Using the CHANNEL button select the appropriate channel. 

3.  Use headphones in the Monitor Socket. 

4.  Select Mono or Stereo. 

5.  Select  Level  as  appropriate.  Microphone  or  Microphone  +  Phantom 

power as required. 

6.  Adjust the Gain so that the Level Indicator peaks at 0dB when speaking 

loudly into the microphone. 

7.  Adjust Compression to get the quietest sounds to the required level. 

8.  Adjust the EQ Low and EQ High for the required tonal quality. 

9.  Select Output to Bus X, Bus Y or Both Busses as required. 

10. Select Priority as required. 

11. Set  the  Gate  Attenuation  (Off  Attenuation)  to  the  level  that  is  required 

when the microphone is not active. This can be set to between 6dB and 
40dB and completely muted. 

12. Set the Detector Type to Auto speech detection.  

13. Set  the  Hold  time  setting  required  50mS,  100mS,  200mS,  500mS, 

1

 

second and 2 seconds. 

14. Decide if the channel should be included in the NOMA calculation. 

15. Connect  any  further  microphones  to  the  remaining  input  channels  and 

carry out stages 2 to 13. 

16. Select  the  Output  A+B  Channels  and  select  the  source  for  the  output 

channel A and Channel B.  

17. Select the Output A+B Channel Gain and adjust the ChA and ChB output 

levels  to  the  required  nominal  level.  Typical  levels  for  microphone  use 
are  –40dBV  and  for  line  levels  0dBV  or  –10dBV.  The  channel  A  and 
channel B gain controls can be either set together or individually.  

Содержание MR88

Страница 1: ...CLOCKAUDIO MR88 Automatic Microphone Mixer Version 4 2 Clockaudio Limited 22 Arnside Road WATERLOOVILLE Hampshire UK Tel 44 0 2392 251193 Fax 44 0 2392 251201 Email sales clockaudio co uk...

Страница 2: ...Function 11 Gating Off Attenuation Level Control 11 Detector Adjustable Detector Control 12 Hold Time 12 NOMA Number of Open Microphones Attenuated Control 12 System Functions 13 Priority 13 Last Act...

Страница 3: ...A information extending throughout With two independent output channel busses provided the MR88 to be used as a genuine 8 X 2 mixer The input level control and priority system of this mixer makes it u...

Страница 4: ...r both output channel busses Output Features 2 Channel balanced line outputs on XLR connectors Independent or linked gain control of output channels Mixed output available from any mixers in chain for...

Страница 5: ...Input Channels 1 8 4 Function Buttons Selects set up functions for each channel 5 Rotary Control Adjusts the settings on each function 6 LED Level meter Indicates peak output level of the selected cha...

Страница 6: ...input channels are required Uses standard RJ45 network leads 4 Balanced Outputs The MR88 has two XLRM type connectors with individually or linked adjustable output gains to give nominal output levels...

Страница 7: ...EREO Gain Left STEREO Gain Left STEREO Gain Left STEREO Gain Left STEREO Gain Left STEREO Gain Left Last One on STEREO Gain Right STEREO Gain Right STEREO Gain Right STEREO Gain Right STEREO Gain Righ...

Страница 8: ...9999 change digit 2 EQ Hi 12dB 12dB EQ Hi 12dB 12dB EQ Hi 12dB 12dB Security Lock Code 0000 9999 change digit 3 Output to Off BusX BusY BusX BusY Output to Off BusX BusY BusX BusY Output to Off BusX...

Страница 9: ...Channel A and B Pressing the CHANNEL buttons move forwards and backwards through Channels 1 to Channel 8 System and Output A B channels The FUNCTION buttons move up or down through the available funct...

Страница 10: ...t Channels 1 2 3 4 5 6 or 7 8 are considered as a stereo pair This reduces the number or setups required for a stereo music source Each stereo pair has only one setting for Input Level compression EQ...

Страница 11: ...en set to Output Bus Y the pair is placed as mono onto the Output Bus Y When set to Output Bus X Y the pair is placed as mono onto the Output Bus X and as mono onto the Output Bus Y When set to Stereo...

Страница 12: ...rol as a manual mixer Detector Forced Off is used to make the selected channel never trigger on sound It can be used in conjunction with external control as a manual mixer Hold Time Hold time is the t...

Страница 13: ...same priority are locked out until the controlling microphone goes silent Switching between microphone channels can be controlled from very fast to up to 2 seconds depending upon application Last Act...

Страница 14: ...Control In 8 5 Control In 7 18 Control In 6 6 Control In 5 19 Control In 4 7 Control In 3 20 Control In 2 8 Control In 1 21 Gnd 9 Gnd 22 5V 10 VCA1 Top 23 VCA1 Wiper 11 VCA1 Gnd 24 VCA2 Top 12 VCA2 W...

Страница 15: ...Out 5 3 Control Out 6 16 Control Out 7 4 Control Out 8 17 Control In 8 5 Control In 7 18 Control In 6 6 Control In 5 19 Control In 4 7 Control In 3 20 Control In 2 8 Control In 1 21 Gnd 9 Gnd 22 5V 10...

Страница 16: ...5 Control In 7 18 Control In 6 6 Control In 5 19 Control In 4 7 Control In 3 20 Control In 2 8 Control In 1 21 Gnd 9 Gnd 22 5V 10 VCA1 Top 23 VCA1 Wiper 11 VCA1 Gnd 24 VCA2 Top 12 VCA2 Wiper 25 VCA2...

Страница 17: ...Channel B VCA2 OFF VCA1 Channel A and B VCA2 OFF VCA1 Channel A VCA2 Channel B Connection to the external control port is as follows Control Out 1 1 Control Out 2 14 Control Out 3 2 Control Out 4 15 C...

Страница 18: ...6 Control In 6 7 Control In 4 8 Control In 2 9 Gnd Chassis 10 5V Output 100mA Max 11 VCA 1 Wiper 12 VCA 2 Top 13 VCA 2 Gnd Chassis 14 Control Out 2 15 Control Out 4 16 Control Out 6 17 Control Out 8...

Страница 19: ...mix is fed back up the chain from the last mixer making the full mixed output available from any of the mixers in the chain Priority and control extends throughout the entire chain The practical limi...

Страница 20: ...equired tonal quality 9 Select Output to Bus X Bus Y or Both Busses as required 10 Select Priority as required 11 Set the Gate Attenuation Off Attenuation to the level that is required when the microp...

Страница 21: ...L and FUNCTION buttons for 3 seconds A warning message will be displayed that the mixer is about to be locked during this 3 seconds Releasing the keys will abort the locking process After the 3 second...

Страница 22: ...dB on Meter Pre amp Out 10 dBV Balanced 60 dBV to 4 dBV Level set on front panel Frequency Response 20Hz to 20kHz THD N 70 dB Max NOMA Attenuation 20 dB Phantom Power 48V Power Supply 15Vdc 3 4A Exter...

Отзывы: