7
Now carefully remove from the foam packing the IR sensor, remote control
and safety cable fixing kits and set aside. Next remove the top bezel
containing the magnet assembly and Tini Q microphone connector.
1. Carefully feed the Tini Q microphone connector through the lower bezel
and push fit the top part of the bezel over the lower bezel, making sure the
magnet assembly is inside the top part of the bezel.
2. Connect the microphone on to the TINI Q connector (push fit).
Any kinks or bends in the cable can be straightened by gripping the cable with your
hands and passing it through a clean dry cloth a few times. Connect the ceiling bezel
plug into SK2 on the main unit,
IMPORTANT: For safety reasons the frame to ceiling tile fixing eye bolt (2 at
each end of the bracket) are used to secure the frame in place and also used to
suspend the CCRM 4000 and bracket. It is suggested that the cable hook is
attached to the eye bolts leaving the bare wire end to a secure fixing such as a
ceiling truss or any structure capable of taking 7Kgs of weight. The cable
length is 2 Metres (78").