2
Features
Control ports allow DSP connection and Link / daisy chain expansion to other
CCRM 4000 Retracta units.
A positive (+2.5V to +12V) signal applied to the MASTER DSP control port will
simultaneously operate all slave units connected to the master.
Logic Hi / Lo for DSP mute detection port.
Master & Slave units are identical in construction. Two rotary 0-9 digital
decimal encoders are used to set Master (00) and 01
– 99 determines slave
designation. The factory default is set to Master (00).
RJ45 socket allows easy and fast connection of the audio to mixer or DSP. A
9-48 Volt phantom power is required.
IR remote control is supplied with the master unit. Remote control can be
used to activate the units in the absence of a DSP.
IR receiver sensor with integral green programme mode LED and red range
LED (supplied with master unit).
Audio cable length 2.5 Metres.
Supplied with a Tri element microphone.
Up to 99 slave units can be daisy chained to the master.
Ceiling bezel fitted with detection switch.
Universal mains switched mode power supply available as separate item.
Operates up to 4 units.
Automatic safety detection for cable hang-ups.