GENERAL WARNINGS

MANUAL PURPOSE 

This manual has been designed to enable the unit to be 
installed, started up and maintained correctly. 

MANUAL INSTRUCTIONS 

It is essential to observe these instructions. 
The manufacturer declines all liability for any damage that 
may be caused whether directly or indirectly to persons or 
things if these instructions are not heeded. 

MANUAL STORE 

This manual and the unit’s wiring diagram should be 
carefully stored so that they are readily available to the 
operator when required. 

EXPERT PERSONAL 

The unit must be installed, tested and maintained by expert 
personal who meet the relevant legal requirements (Italian 
law No. 46 of 5/3/1990). 

LOCAL SAFET REGULATION INSTALLATION  

The installation must be performed observing the local 
safety regulations. 

POWER SUPPLY 

Make sure the power supply conforms to the data on the 
unit’s rating plate, located inside the door of the main 
electrical panel. 

PACKAGING 

The packaging material (plastic bags, polystyrene foam, 
nails, etc.) is potentially dangerous and should therefore be 
kept away from children and recycled in compliance with 
the local regulations in force. 

MAINTENANCE 

Before performing any service operations, cut off the power. 
Perform the operations in conformity with the local 
regulations in force. 

PERIODICAL INSPECTIONS  

Perform periodical inspections to locate possible loosened 
or broken parts. If the repairs are not performed, there will 
be a higher risk for things and peoples to become damaged 
and injured.  

FAULT – POOR OPERATION 

Switch off the unit in the event of faults or poor operation. 

REPAIR  

Only have repairs carried out by a service centre authorised 
by the manufacturer, and insist on the use of original spare 
parts only. 
Failure to comply with the above may compromise the 
safety of the unit. 

MODIFICATIONS 

The manufacturer will not accept any responsibility, and the 
warranty will lapse, in the event of electric and/or 
mechanical modifications. Any modification which is not 
formally authorized, and which does not respect the 
instructions given in this manual, will cause the warranty to 
lapse. 

INTENDED USE 

The unit must only be used for the specific purpose it was 
designed :  

The unit is designed to cool/heat water or a water and 
glycol mix for air-conditioning, within the limits defined 
in the technical bulletin and this manual. 

Any use other than that specified does not imply any 
commitment or constraint by the manufacturer in any way 
whatsoever. 

ADDITIONAL SAFETY PRECAUTIONS 

This unit has been especially designed and manufactured 
so to prevent any risk to persons and health hazard. 
For this reason, design solutions fit to eliminate (where 
possible) any cause of risk and sensibly reduce the 
probability of danger have been adopted. 
Please refer to the "Residual Risks" section of this manual 
and strictly observe the behaviour prescriptions listed there 
in order to prevent any possible risk that hasn’t been 
possible to avoid in the design stage. 

DATA UPDATING 

The manufacturer may be able to modify the data without 
prior notice as a consequence of constant improvements.  

REGULATIONS AND 
CERTIFICATIONS

 

UNI EN ISO 9001 CERTIFICATION 

Clivet S.p.A., in order to guarantee customer satisfaction, 
has chosen the ISO 9001 Quality System as the reference 
for all its business activities. This is demonstrated by the 
company’s commitment to ongoing improvements in the 
quality and reliability of its products; its sales, design, 
purchasing, production and after-sales service activities are 
the means used to reach such purpose. 

 

CE MARK

 

 

 

 

Clivet products bear the CE mark, in compliance with the 
requirements of the following EC directives, including the 
latest amendments, and with the corresponding national 
approximated legislation: 

• 

- 98/37/CE 

• 

- 89/336/CEE as modified by the directives 92/31/CEE 
and 93/68/CEE 

• 

- 73/23/CEE as modified by the directive 93/68/CEE 

• 

- 97/23/CE 

 

Содержание WSAT-XEE 102

Страница 1: ...WSAT XEE 82 102 122 162 182 222 262 302 AIR COOLED WATER CHILLER FOR OUTDOOR INSTALLATION Installation and Use Manual M0G140F7 01 06 11 07...

Страница 2: ......

Страница 3: ...O THE MAINS 17 FUNCTIONAL CONNECTIONS 18 SYSTEM COMPOSITION 19 S T A R T U P 2 1 PRELIMINARY CHECKS 21 REFRIGERANT SYSTEM 21 WATER SYSTEM 21 ELECTRICAL SYSTEM 21 VERIFy tensions absorptions 21 UNIT EQ...

Страница 4: ...AL NUMBER This provides unique identification of the machine It makes it possible to trace the specific features of the unit and to identify the components installed in it Without this number it is no...

Страница 5: ...rnal environment 1 The compressor compresses the refrigerant gas placing it at high pressure and high temperature 2 In the external coil the refrigerant is cooled and the heat is released into the env...

Страница 6: ...mode Minimize the consumptions maintaining the system at a safety temperature in SUMMER MAINTENANCE function Put the unit in OFF parameter 44 must be 1 Modify the water temp in COOLING Control parame...

Страница 7: ...to the initial point See which ALARM blocks the unit E xx is automatically visualized A L A R M S T A T U S S E T See the alarm log starting from the most recent until the farthest one A L A R M S T...

Страница 8: ...urer will not accept any responsibility and the warranty will lapse in the event of electric and or mechanical modifications Any modification which is not formally authorized and which does not respec...

Страница 9: ...rized entry GENERAL RISKS A smell of burning smoke or other indications of serious irregularity could signal the onset of situations liable to cause damage to persons or property or to the unit itself...

Страница 10: ...etan R125 50 in weight CEE No Non applicable for mixtures Commercial name 03 Hazard identification Hazard identification Liquefied gas Vapours are heavier than air and can cause choking by reducing th...

Страница 11: ...ap of the valve if supplied is correctly assembled Verify that the cap if supplied is well assembled and that there is adequate ventilation Verify that the norms in force are respected 15 Information...

Страница 12: ...ions of the safety norms in force Legislative Decree 626 94 and following modifications Before starting the handling operations Value the critical points during handling stairs flights disconnected ro...

Страница 13: ...subject to flooding 5 Consider the maximum level which can be reached by snow 6 Verify that the fixing supporting points are level and suitable to support the weight of the unit see the weight and th...

Страница 14: ...n of expelled air Keep the coil clean Avoid zones with leaves dirt corrosives Avoid snow build up during winter operation 1 3 2 1 elastic joint 2 floating floor 3 soundproofing Provide windbreaks in l...

Страница 15: ...the system by verifying that o no taps are closed so they can not trap the water even after emptying o there are no low points where the water can stagnate even after emptying blow if necessary INTAL...

Страница 16: ...side in the figure Storage content size 82 122 80 litres optional size 162 302 130litres RECOVERY EXCHANGER OPTIONAL The unit can be equipped with exchangers to recover the condensation heat The recov...

Страница 17: ...tension and that are able to emit electromagnetic disturbances Do not lay the cable near devices which can generate electromagnetic interferences Do not lay the cables parallel to other cables cable...

Страница 18: ...age at the terminal ends is 24v ac and maximum power is 1A ac1 SET POINT COMPENSATION WITH 4 20 MA SIGNAL WATER RESET It optimizes the energetic efficiency of the unit by automatically changing the se...

Страница 19: ...16 SYSTEM COMPOSITION The system is composed of the following modules Some are optional that could be not installed Some are supplied in packages separate from the unit check the shipping document des...

Страница 20: ...he COMMUNICATION PROTOCOL about the COMPACT MEDIUM electronics The total length of each single serial line don t have to be over 1000 metres The potential difference between the ground of two RS485 sw...

Страница 21: ...glycol percentage is suitable for the type of use envisaged weight of ethylene glycol 10 20 30 40 Freezing point 4 C 9 C 15 C 23 C Safety temperature 2 C 7 C 13 C 21 C Check that the circulating pump...

Страница 22: ...fference between the temperature of exchanger return and supply water corresponds to power according to this formula unit cooling power kW x 860 Dt C x flow rate L h The cooling power is shown in the...

Страница 23: ...time and only at the SCAN TIME expiring The scan time is not fixed but it changes in function of the margin between the water supply temperature and the Set point value Higher is the margin value bot...

Страница 24: ...ically to the Winter mode Defrosting is managed according to the outside temperature and humidity in the air more humidity frequent defrosting outside temperature next to 0 C frequent defrosting By th...

Страница 25: ...n to function with glycoled water come out from the premise with standard parameters After having added glycol ethylene to water the technician will properly set the plant Parameter to modify 32 Summe...

Страница 26: ...R SERVICE KEYBOARD Visible status from remote keyboard or service keyboard INDEX DESCRIPTION VALUE 1 Current Set Point C 2 Temperature drop in degrees centigrade given by the compressor including comp...

Страница 27: ...n for machine safety Before resetting the alarm discover and remove the cause repeated resetting could cause irreversible damage To avoid this the unit can only be reset MANUALLY from the keyboard onl...

Страница 28: ...8 Faulty or disconnected pressure transducer 2 Auto S 9 Water Reset return in short circuit or out of range Auto E 10 Faulty or disconnected external RH probe Auto E 11 High pressure 1 MANUAL E 12 Low...

Страница 29: ...m the surface Using an air pressure gun clean the aluminum surface of the battery Be careful to direct the air in the opposite direction of the fan air movement Hold the gun parallel to the fins to av...

Страница 30: ...s as well Refer to local actuation norms In Italy refer to the Ministerial Decree of 1 st December 2004 no 329 and following modifications which defines the performances to be executed the units of 1...

Страница 31: ...ions OVERHEATING return temperature Saturation temperature Return pressure 7 2 bar Return temperature 7 3 C overheating 7 3 0 8 6 5 C SUBCOOLING condensing temperature pressure liquid temperature Cond...

Страница 32: ...6 4 8 9 68 15 8 25 57 26 8 45 77 37 8 60 50 5 0 8 69 16 0 26 01 27 0 46 08 38 0 60 73 5 2 7 73 16 2 26 46 27 2 46 38 38 2 60 96 5 4 6 79 16 4 26 90 27 4 46 69 38 4 61 20 5 6 5 87 16 6 27 33 27 6 46 99...

Страница 33: ...in cooling 1 low air temperature see operating limits 2 low water temperature see operating limits 3 insufficient water flow to the exchanger high thermal difference between input and output 4 not CON...

Страница 34: ...ng insufficient refrigerant charge FAN PROTECTION 1 Identify the part on the wiring diagram 2 fan mechanically jammed bearings drive belt if present 3 Loose electric contacts terminals leads broken 4...

Страница 35: ...5 19085 29 5 8456 50 5 4128 12 5 47660 9 0 18701 30 0 8300 51 0 4066 12 0 46571 9 5 18326 30 5 8147 51 5 4005 11 5 45510 10 0 17960 31 0 7998 52 0 3944 11 0 44475 10 5 17602 31 5 7852 52 5 3885 10 5 4...

Страница 36: ...must be stored in special containers When recovering the substances present in the unit all measures must be taken to avoid damaging persons and things and polluting the surrounding area Awaiting dism...

Страница 37: ...els Nr 1 POWER SUPPLY Standard power supply V 400 3 50 N NOISE LEVELS Sound pressure level 1 m dB A 60 60 60 61 62 62 64 64 DIMENSIONS Length mm 1703 1703 1703 1932 1932 1932 2332 2332 Depth mm 675 67...

Страница 38: ...egulations with respect to the EUROVENT 8 1 certification the sound levels refer to the unit at full load in the rated test conditions The sound pressure level refers to a distance of 1m from the exte...

Страница 39: ...epth mm 675 675 675 Height mm 1209 1209 1209 W1 kg 98 99 115 W2 kg 58 59 68 W3 kg 85 87 101 W4 kg 64 65 76 Operating weight kg 305 310 360 Shipping weight kg 315 320 370 1 COMPRESSOR 2 FINNED EXCHANGE...

Страница 40: ...1100 1100 1100 Height mm 1417 1417 1417 W1 kg 166 173 182 W2 kg 99 103 108 W3 kg 146 151 160 W4 kg 109 113 120 Operating weight kg 520 540 570 Shipping weight kg 530 550 580 1 COMPRESSOR 2 FINNED EXC...

Страница 41: ...pth mm 1100 1100 Height mm 1417 1417 W1 kg 166 173 W2 kg 99 103 W3 kg 146 151 W4 kg 109 113 Operating weight kg 520 540 Shipping weight kg 530 550 1 COMPRESSOR 2 FINNED EXCHANGER 3 HELICAL FANS 4 PLAT...

Страница 42: ......

Страница 43: ......

Страница 44: ...24 info clivet nl CLIVET TFAIRSYSTEMS P LTD Malur INDIA Tel 91 8151 232683 5 Fax 91 8151 232684 info clivettfa com CLIVET SPA BUREAUDE LIAISON EN FRANCE Verrier s le Buisson FRANCE Tel 33 0 1 69 20 25...

Отзывы: