M0G140F7-01 06/11/07
pag
37
TECHNICAL DATA
SIZE 82
102
122
162
182
222
262 302
Cooling
Cooling capacity
1 kW
24,3
28,2 33,7 40 45,9 54,4 64,1 72,2
Comp. input power
1 kW
8,5 10 12,1 13,5 16 19,2 22,3 25,5
Total input power
2 kW
8,9
10,4 12,5 14,2 16,7 19,9 23,4 26,6
EER 1
2,73
2,72
2,71
2,81 2,74 2,73 2,74 2,71
ESEER
4,32 4,48 4.18 4,20 4,34 4.47 4,19 4,06
COMPRESSORS
Compressor type
3
SCROLL
No. of compressors
Nr
2
Capacity
control
steps
Std
Nr
3 3 2 3 3 3 3 2
Refrigerant circuits
Nr
1
Refrigerant charge (C1)
l
3,61 3,72 3,54 5,76 5,76 6,65 7,39 8,28
INTERNAL EXCHANGER
Type of exchanger
4
PHE
No. Of exchangers
Nr
1
Water flow-rate
1
l/s
1.2
1.3 1.6 1.9 2.2 2.6 3.1 3.4
Pressure
drop
kPa
48 47 41 43 43 38 40 42
Useful pump discharge head
1 kPa
132
126
120
104
88
148
139
131
EXTERNAL SECTION FANS
Fan type
5
AX
No.
of
fans
Nr
2 2 2 4 4 4 6 6
Standard
air-flow
1
l/s 2545 2538 2514 4933 4875 4778 7196 7145
Installed unit power
kW
0,17
0,17 0,17 0,18 0,18 0,18 0,18 0,18
CONNECTIONS
Water fittings
1" 1/4
2"
HYDRAULIC CIRCUIT
Max water side pressure
kPa
550
Safety valve calibration
kPa
600
EXPANSION VESSEL
Expansion vessel capacity
l
5
Maximum water side pressure
550
No. of expansion vessels
Nr
1
POWER SUPPLY
Standard power supply
V
400/3/50+N
NOISE LEVELS
Sound
pressure
level
(1
m)
dB(A)
60 60 60 61 62 62 64 64
DIMENSIONS
Length
mm 1703 1703 1703 1932 1932 1932 2332 2332
Depth
mm 675 675 675 1100 1100 1100 1100 1100
Height
mm 1209 1209 1209 1417 1417 1417 1417 1417
Packing volume
m
3
1,8
1,8
1,8 4 4 4 4,5
4,5
STANDARD UNIT WEIGHTS
Shipping
weight
kg 315 320 370 530 550 580 675 690
Operating
weight
kg 305 310 360 520 540 570 665 680
(1) data referred to the following conditions :
internal exchanger water = 12/7°C
external exchanger air intake 35°C
(2) Total absorbed power is given by the compressor absorbed power
+ fan absorbed power + auxiliary circuit absorbed power.
(3) SCROLL = scroll compressor
(4) PHE = plates
(5) AX = axial-flow fan
SETTING THE CUT-OUT DEVICES AND CONTROLS
On
Off
High pressure switch
(kPa)
4200
3300
Low pressure switch
(kPa)
200
350
Max compressor starts per hour
(n°)
10
Antifreeze protection
(°C)
4
6,5
Safety discharge thermostat
(°C)
120
FOULING CORRECTION FACTOR
INTERNAL EXCHANGER
m² °C/W
F1
FK1
0.44 x 10^(-4)
1,00
1,00
0.88 x 10^(-4)
0,97
0,99
1.76 x 10^(-4)
0,94
0,98
The cooling performance values provided in the tables are based on the external exchanger having clean plates (fouling factor 1). For different
fouling factor values, multiply the performance by the coefficients shown in the table.
F1 =
Cooling capacity correction factors
FK1 =
Compressors input power correction factors