-- 8 --
a.
***** POSITIONS
Default settings are not important because the position
depends on the location of the Index.
Using the “teach-in” mode, this parameter can be set the
following way:
1. Go to the desired parameter (for example needle up)
The display reads the parameter and a number
2. Turn the hand wheel to the desired position (needle-up)
The display does not change
3. Press the NEEDLE-UP/NEEDLE-DOWN” button
The display changes the number, this is the new position
This number can be corrected by using the ARROW-UP
Or ARROW-DOWN button
5.3.1 DN. POS
Needle Down Position
This parameter can be changed by:
a)
Arrow-Up / Arrow-down Buttons
b)
Teach-in mode
5.3.2 UP POS
Needle Down Position
This parameter can be changed by:
a)
Arrow-Up / Arrow-down Buttons
b)
Teach-in mode
5.4.0 ****** MISCELEN
(Miscellaneous)
Presser foot duty cycle:
Due the voltage is too high to turn a solenoid permanent on all time,
the current is turned on only permanently a short time, after that,
the current has to be chopped.
For example: Duty cycle 40% means 40% on, 60% off
If the duty cycle is too low, the solenoid will not stay on.
If too low, the solenoid will turn too hot!
5.4.1 PF 100%
Presser foot on 100 %
Range
10 to 2000
Steps:
10
Default:
200
5.4.2 PF DUTY Presser foot duty cycle
Range
10 to 100
Steps:
10
Default:
50 (50%)