![Clinton 1095E Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/clinton/1095e/1095e_manual_2625286011.webp)
-- 10 --
7.1.0 Using the Built-in Test Program
To enter: Press simultaneously the ARROW- RIGHT and the SBT button., release the
ARROW-RIGHT button first! Otherwise you are back in the main program!
The display should read:
TEST MODE
To go to the first group, press the “ARROW-ROUND” button
The display reads:
TEST TREADLE
for about 2 seconds
Then it reads the position of the threadle:
This can be:
1. NEUTRAL
2. FORWARD and a number
c)
HEEL 1
d)
HEEL 1 / HEEL 2
If the threadle is in forward position, the displayed number is the reading of the
ADC- converter.
The lowest number should be below ten (10) and the highest number at least 245
To go to the next group, press the “ARROW-ROUND” button again
The next group is:
test inputs
(this will be displayed for two seconds)
Then activated inputs are displayed
If no inputs are activated, the display reads
“ ---------------- “
To go to the next group, press the “ARROW-ROUND” button again
The next group is:
test outputs
After two seconds, the display reads:
-1- PRESSERFOOT
To activate the output, press the “NEEDLE-UP / NEEDLE-DOWN button.
To go to the next output, press the “ARROW-UP” button.
The next reading is;
-
2 – CUTTER
To go to the next output, press the “ARROW-UP” button.
To go to the former output, press the “ARROW-DOWN” button
To go to the next group, press the “ARROW-ROUND” button again
The next group is:
test encoder
The display reads: ENCODER “YYYY” ***
***
“YYYY” is a number which represents the position of the encoder.
Turn the hand wheel and the number should read between 0 and 2000.
Turn ‘CCW’ to count up and turn ‘CW’ to count down.