WARNINGS
– In case of fault and/or incorrect equipment operation, deactivate it, without making any repairs or taking any direct action .
Apply only to qualified technical personnel .
– Boiler installation and any other assistance and/or maintenance activity must be carried out by qualified personnel persuant
to Standard CEI 64-8 . Under no circumstances, the devices sealed by the manufacturer can be tampered with .
– It is absolutely prohibited to block the intake grilles and the aeration opening of the room where the equipment is installed .
– The manufacturer shall not be held liable for any damage caused by improper use of the appliance .
– This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety . Children should be supervised to ensure that they do not play with the appliance .
LIGHTING AND OPERATION
BOILER IGNITION (fig . 25)
The first ignition of the boiler must be carri-
ed out by qualified technical personnel .
Successively, if it is necessary to start up the
boiler again, adhere strictly to the following
instructions: open the gas tap to allow the
flow of the fuel and move the main switch
of the system to “ON” .
After a stop, wait for about 30 seconds be-
fore restoring functioning conditions do that
the boiler can perform the control sequence .
If the green led is on, this indicates the pre-
sence of voltage .
Keys lock
If the device is not used, the keys will be
locked 15 minutes after the last setting was
made (PAR 5 by default) and the display
light switches off .
To set one of the operating modes, press
any of the keys for more than two seconds
(the display will indicate one to four seg-
ments progressively before unlocking the
controls) .
Winter
Press the key () of the controls to activate
the winter mode fun-
ctioning (heating and
D .H .W .) . The display will be as shown in the
figure .
Summer
Press the key () of the
controls to activate
the summer mode functioning (only the
production D .H .W .) . The display will be as
shown in the figure .
REGULATION OF THE WATER TEMPERATU-
RE FOR HEATING (fig . 26)
To set the temperature of the water for hea-
ting, press the key () of
the controls .
1
2
3
4
1
2
3
4
1
2
3
4
USER INSTRUCTIONS
91
IT
ENG
ES
1
2
3
4
Fig . 25
ATTENTION: for set up modality of function more adapted to graze the keys simply .
One beep indicates that the boiler has taken command . If PAR 5 is disabled, the
display remains lit .
1
2
3
4
1
2
3
4