2
DIP
Position
Function
Switch1
ON
Test Mode
OFF
Normal Mode (default)
Switch2
ON
LED Indicator Enable (default)
OFF
LED Indicator Disable
Switch3
ON
PIR Camera facing a wall
within 10 m
OFF
PIR Camera facing an open
space (no wall within 10 m)
(default)
Switch4
ON
PIR Camera facing a lawn
(default)
OFF
PIR Camera facing a
concrete/stone ground
DIP
Sensitivity Level
Switch5
Switch6
ON
ON
Low; 75 cm/60 kg pet (default)
ON
OFF
High; 50 cm / 35 kg pet
OFF
ON
Reserved
OFF
OFF
Reserved
DIP
Position
Function
Switch7
ON
Double Knock Enable (default)
OFF
Double Knock Disable
Switch8
ON
Pet Immune Enable (default)
OFF
Pet Immune Disable
⚫
When the PIR Camera is in fault conditions (tamper open or low battery condition persists), each time it transmits a
detected movement, the LED will flash for 6 times.
⚫
After the Test button is pressed once to enter Test Mode, the LED will flash for 60 seconds to indicate that the PIR
motion sensor camera is warming up.
⚫
In Test mode, the LED will turn on for 2 seconds whenever a movement is detected.
<
<
N
N
O
O
T
T
E
E
>
>
The LED indicator can be enabled by setting the DIP Switch2 to ON position. Please refer to
DIP Switch Position
Table
for details.
⚫
⚫
I
I
m
m
a
a
g
g
e
e
C
C
a
a
p
p
t
t
u
u
r
r
e
e
When the alarm system is armed, the PIR Camera will capture 1, 3 or 6 alarm images in 640 x 480 or 320 x 240
resolutions (programmable from Control Panel) upon movement detection. You can also manually request the PIR
Camera to take a picture through the Control Panel. The captured images will be transferred to the Control Panel for
visual alarm verification.
⚫
Warm Up Period
The PIR Camera will warm up for 60 seconds in the following conditions:
⚫
When the PIR Camera is turned on by the Control Panel system upon entering arm mode or entering arm mode with
fault conditions.
⚫
When the test button is pressed once to enter Test Mode.
The Red LED will flash slowly during warm up period. During the 60-second warm up period, the PIR Camera will not be
activated.
⚫
⚫
T
T
e
e
s
s
t
t
M
M
o
o
d
d
e
e
⚫
The PIR Camera can be put into Test mode for 10 minutes by pressing the Test button once. In Test mode, the sleep
timer and image capture functions are disabled. LED indicator is enabled to light up for two seconds whenever a
movement is detected. The PIR Camera will automatically exit Test Mode after 10 minutes, and return to normal mode.
⚫
To put the PIR Camera into constant Test mode, please adjust DIP switch1 to ON position (Please refer to
DIP Switch
Position Table
).
⚫
⚫
S
S
u
u
p
p
e
e
r
r
v
v
i
i
s
s
i
i
o
o
n
n
S
S
i
i
g
g
n
n
a
a
l
l
⚫
After installation, the PIR Camera will automatically transmit Supervisory signals periodically to the Control Panel at
random intervals of 30 to 50 minutes.
⚫
If the Control Panel has not received the signal from the PIR Camera for the preset period of time, the Control Panel
will indicate on its display that the particular PIR Camera is experiencing an out-of-signal problem.
⚫
⚫
S
S
l
l
e
e
e
e
p
p
T
T
i
i
m
m
e
e
r
r
⚫
The PIR Camera features an automatic
“sleep time” of approximately one minute for power conservation. After
transmitting a detected movement, the PIR Camera will not retransmit for one minute. Any further movement detected
within this one-minute sleep period will extend the sleep time by another minute. This way, continuous movement in
front of PIR Camera will not unduly exhaust the battery.
⚫
⚫
D
D
o
o
u
u
b
b
l
l
e
e
K
K
n
n
o
o
c
c
k
k
F
F
u
u
n
n
c
c
t
t
i
i
o
o
n
n
⚫
The PIR Camera has a double knock function. If the double knock function is enabled, the PIR Camera will report an
alarm to the control panel only if two movements are detected within 10 seconds. If the double knock function is
disabled, the PIR Camera will report an alarm to the control panel when a movement is detected.
⚫
⚫
T
T
a
a
m
m
p
p
e
e
r
r
P
P
r
r
o
o
t
t
e
e
c
c
t
t
i
i
o
o
n
n
⚫
The PIR Camera is protected by an internal tamper switch which is compressed when the PIR Camera is hooked onto
the mounting bracket. When the PIR Camera is removed from the mounting bracket, the tamper switch will be
activated and the PIR Camera will send a tamper open signal to the control panel to remind the user of this condition.
⚫
⚫
D
D
I
I
P
P
S
S
w
w
i
i
t
t
c
c
h
h
P
P
o
o
s
s
i
i
t
t
i
i
o
o
n
n
T
T
a
a
b
b
l
l
e
e
The function of each DIP Switch is listed in the table below. The DIP Switch is either ON or OFF. Top position indicates ON
and bottom position indicates OFF.
<NOTE>
After changing Dip Switch settings, please re-power on the PIR Camera for it to operate with new Dip Switch Settings.
ON
OFF