Climax VST-852Pro-Ultra Скачать руководство пользователя страница 2

 

2

5. Battery 

Compartment 

6.  Jumper Switch (JP2)   

   

 

- Jumper On: After transmitting for a detected movement, any further movement detection will 

transmit the event code again (and the captured images) (

default

). 

- Jumper Off: PIR Camera has a “

sleep time

” of approximately 1 minute to conserve power.   

7.  Jumper Switch (JP1)   

   

   

- Jumper On: the Blue LED is enabled (

default

). 

- Jumper Off: the Blue LED is disabled.   

8. Battery 

Insulator 

 

           

 

Features 

z

z

 

 

I

I

m

m

a

a

g

g

e

e

 

 

C

C

a

a

p

p

t

t

u

u

r

r

e

e

 

 

When the alarm system is armed, the PIR Camera will capture 3 alarm images (Quality: 640 x 480 
resolution, or VGA) upon movement detection. You can also manually request the PIR Camera to 
take a picture through CIE. The captured images will be transferred to ZigBee coordinator or CIE 
for user to view. 

z

z

 

 

W

W

a

a

r

r

m

m

 

 

U

U

p

p

 

 

P

P

e

e

r

r

i

i

o

o

d

d

 

 

When the ZigBee network coordinator or system control panel enters arm mode, or when PIR 
Camera is put into Test Mode, the PIR Camera will warm up for 30 seconds. Do not trigger the 
PIR Camera during the 30-second warm up period. If the PIR Camera is under low battery, the 
Blue LED will light up during the warm up period. 

z

z

 

 

S

S

l

l

e

e

e

e

p

p

 

 

T

T

i

i

m

m

e

e

r

r

 

 

When 

Jumper Switch 2

 is set to Off, the PIR Camera has a “

sleep time

” of approximately 1 

minute to conserve power. After transmitting for a detected movement, the PIR Camera will not 
retransmit for 1 minute. Any detected movement during this period will extend the sleep time by 
another minute. Continuous movement in front of the PIR Camera will therefore not exhaust the 
battery.

 

z

z

 

 

B

B

a

a

t

t

t

t

e

e

r

r

y

y

 

 

a

a

n

n

d

d

 

 

L

L

o

o

w

w

 

 

B

B

a

a

t

t

t

t

e

e

r

r

y

y

 

 

D

D

e

e

t

t

e

e

c

c

t

t

i

i

o

o

n

n

 

 

The PIR Camera uses two

 1.5V “AA” Lithium batteries 

in series connection as its power source. 

The batteries are pre-installed in the PIR Camera. To activate the batteries, pull out the battery 
insulator. 
The PIR Camera features Low Battery Detection function. When the battery voltage is low, the 
PIR Camera will transmit Low Battery signal to the coordinator in ZigBee network. If movement is 
detected under Low Battery condition, the Blue LED will light up for 2 seconds. 
When changing battery, after removing the old battery, press the Function Button twice to fully 
discharge before inserting new batteries 

z

z

 

 

S

S

u

u

p

p

e

e

r

r

v

v

i

i

s

s

i

i

o

o

n

n

 

 

T

he PIR Camera will transmit a supervision signal to report its condition regularly according to user 

setting. The factory default interval is 30 minutes. The user can also press the Function Button 
once to transmit a supervision signal manually. 

z

z

 

 

T

T

e

e

s

s

t

t

 

 

M

M

o

o

d

d

e

e

 

 

z

 

Test mode is for you to check the PIR camera’s detection range (not shooting coverage). 

z

 

To enter Test mode, press and hold the Function button over 3 seconds and release the button 
to enter the Test mode for 3 minutes. 

z

 

The PIR camera will warm up for 30 seconds. Please do not trigger the Camera during this 
warming-up period.   

z

 

After the warm-up period, you can trigger PIR camera to check IR detection range. If PIR 
camera is triggered, the Blue LED will light up for 2 seconds. 

Jumper On 

The jumper link is inserted 
connecting the two pins.

 

Jumper Off

if the jumper link is removed 
or “

parked

” on one pin.

 

Jumper On 

The jumper link is inserted 
connecting the two pins.

 

Jumper Off

if the jumper link is removed 
or “

parked

” on one pin.

 

Отзывы: