Manual Control 

If an optional Local Switch is connected, the user can press and hold the button on the up/down 
Local Switch (S1 up; S2 down) for 1 second to control the shutter. When activated, the shutter 
will roll up/down. 
When  the  shutter  is  rolling,  the  user  can  stop  the  shutter  by  pressing  the  opposite  direction 
button. 

 

Z-Wave Network 

After  the  Shutter  Control  has  been  successfully  included  in  a  Z-Wave  network,  the  Z-Wave 
controller can control the shutter  with Z-Wave command Switch Binary Set or Switch Multilevel 
Set, using parameters below: 

 

Value: 0x00~0x63 (0%~99%, 0% = Full Close, 99% = Full Open)   

 

Dimming Duration : 0x00 

  As each up/down movement starts, the Multilevel Switch Start level Change Command is sent to 

initiate  the  transition  to  the  new  level.  While  the  SCM  is  in  motion,  you  can  send  Multilevel 
Switch Stop Level Change Command to stop the SCM. 

 

 

C

C

a

a

l

l

i

i

b

b

r

r

a

a

t

t

i

i

o

o

n

n

 

 

  The Shutter Control default activation time is 

4

 minutes.   

When the Up/Down button is pressed, it will activate the shutter motor for 4 minutes.   
When a Z-Wave command is received from Z-Wave controller, it will determine the shutter travel 
percentage using 4 minutes as basis for calculation. 

  For  the  Shutter  Control  to  work  properly,  its  activation  time  must  be  calibrated  according  to 

actual shutter travel distance. There are two ways to adjust the activation time: 

 

Manual Calibration:

 Calibrate the activation according to procedure below: 

1.  Before calibration, the external local switches must be connected to the Shutter Control. 
2.  Press and hold the Function button for 3 seconds and release to enter Calibration mode. 

The Shutter motor will roll up for 4 minutes when the Shutter Control enters Calibration 
mode. 

3.  Wait  for  4  minutes  for  Shutter  motor  to  stop  rolling,  then  press 

“Down”  button  to  roll 

down  the  shutter.  (If  less  than  4  minutes  the  shutter  has  reached  the  open  position 
already,  you  can  press  the 

“Down”  button  to  stop  the  shutter  motor.  Then  press  the 

“Down” button again to roll down the shutter.) 

4.  As  soon  as  the  shutter  is  fully  closed,  press  the 

“Up”  button.  The  Shutter  control  will 

record the time it took for the shutter to roll from open to close as the new 

close time

”. 

5.  After the 

“Up” button is pressed the moment the shutter is fully closed, the shutter  will 

roll up towards the open direction. 

6.  Press the 

“Down” button the moment the shutter is fully opened. The Shutter control will 

record to time it took for the shutter to roll from close to open as the new 

open time

”. 

7.  The  Shutter  Control  will  send  a  multilevel  report,  with  its  current  value,  target  value, 

and/or duration, to the controller whenever its level changed. 

 

For  Example,  if  it  takes  the  shutter  30  seconds  to  move  from 

“Up” to  “Down” position, its 

new  close  time  will  be  30  seconds.  After  calibration,  whenever  the 

“Down”  button  is 

pressed, the shutter will roll down for 30 seconds. 

 

If it takes the shutter 40 seconds to move from 

“Down” to “Up” position, its new open time 

will be 40 seconds. After calibration, whenever the 

“Up” button is pressed, the shutter will 

roll up for 40 seconds. 

 

Z-Wave Command: 

Besides manual calibration, users can also adjust the activation time 

by  sending command  from  the  Z-Wave  Controller  with  Configuration  CC command, using 
parameters below: 

Setting 

Parameter Number 

Size 

Value 

Default 

Open Time Setting 

0x01 

0x02 

0x0000~0x00FF 
(sec) 

0x00F0 (240 sec) 

Close Time Setting 

0x02 

0x02 

0x0000~0x00FF 
(sec) 

0x00F0 (240 sec) 

Current Position 

0x03 

0x02 

0x0000~0x0063 
(%) 

0x0063 (99%)   
Full Open 

 

Parameter Number : 0x01~0x03 

 

For parameter 1, users can set the open time (from down to up) to a value that ranges from 
0 to 255 seconds. 
 