This product can be included and operated in any Z-Wave network with other Z-Wave certified
devices from other manufactures and/or other applications. All non-battery operated nodes within the
network will act as repeaters regardless of vendor to increase reliability of the network.
Connect the power to Shutter Control (see manual
’s
Installation
).
Put the Z-Wave gateway or control panel into
Inclusion mode
(please refer to the Z-Wave
gateway or control panel manual).
Within 1.5 seconds, press the Function Button 3 times.
Refer to the operation manual of the Z-Wave gateway or control panel to complete the adding
process.
If the device has already been added (included) into another Z-Wave Gateway/Control Panel,
or if the device is unable to be added into the current Z-Wave Gateway/Control Panel, try
removing it first (see
Removing Device
).
R
R
e
e
m
m
o
o
v
v
i
i
n
n
g
g
D
D
e
e
v
v
i
i
c
c
e
e
(
(
E
E
x
x
c
c
l
l
u
u
s
s
i
i
o
o
n
n
)
)
The device must be removed from existing Z-Wave network before being added into another.
Exclusion Mode
Put the Z-Wave gateway or control panel into
Exclusion mode
(please refer to the Z-Wave
gateway or control panel manual).
Within 1.5 seconds, press the Function Button 3 times and the device will be removed from the
Z-Wave network.
Factory Reset
(Only use factory reset when network Control Panel/Gateway is missing or inoperable).
Factory resetting the device will restore it to factory default settings (i.e. excluded from Z-Wave
network).
Press and hold the Function Button of the device for 10 seconds to factory reset.
R
R
a
a
n
n
g
g
e
e
T
T
e
e
s
s
t
t
To test whether the device is able to communicate with the Z-Wave gateway or control panel:
Put the gateway / panel into range test mode (Walk Test).
Press the Function Button on the device
The gateway / panel should display if the device is within the operation range (please refer to
the operation manual of the gateway / panel).
Installation
Please use the recommended wire size of AWG 16-26 or Ø 1.31-0.129 (mm
²
).
Connect SCM according to the diagram below:
Connect L terminal of SCM to the L terminal of Power Supply.
Connect N terminal of SCM to the N terminal of Power Supply.
Connect O1 terminal of SCM to the Up terminal of the Shutter Motor.
Connect O2 terminal of SCM to the Down terminal of the Shutter Motor.
(Optional local switch)
Connect S1 and S2 terminals of SCM to the L terminal of Power Supply.