Step 1.  Put Keypad in Test mode by entering “

0000

” (default PIN code), then press 

. Keypad will sound 1 

long beep and the Green Active LED will steadily flash. 

Step 2.  Adding Keypad into the Control Panel: 

I.  Put the Control panel into 

/-

 menu and select the 

Add Devices

 sub menu. 

II. Press 

 and then 

1

 when requested. Keypad and Control Panel will beep once. 

III.  Refer to the operation manual of your control Panel under the section of 

/-

 to complete 

the learn-in process. 

Step 3.  After the Keypad is learnt-in, put the Control Panel into 

Walk Test

 mode, hold the Keypad in the 

desired location, press the 

 then 

1

 button to confirm this location is within signal range of the 

Control Panel. 

Step 4.  When you are satisfied that the Keypad works in the chosen location, you can proceed with mounting 

the Keypad following the steps described below (see 

Mounting Keypad)

Step 5.  Setting the Pin Code: 

 

I. Press 

 then 

6

, a long beep will be sound. 

II. Enter 

0000

 (default PIN code) 

III. Press

Χ

, Keypad sounds a long beep. 

IV.  Enter your new 4-digit code. 
V. Press 

#

, Keypad sounds a long beep. 

Step 6.  Press 

 

twice 

to exit Test mode and the installation is completed.

 

 

 

 

z

z

 

 

M

M

o

o

u

u

n

n

t

t

i

i

n

n

g

g

 

 

t

t

h

h

e

e

 

 

K

K

e

e

y

y

p

p

a

a

d

d

:

:

 

 

To mount the Keypad: 

I.  Remove the 2 slide-out sections of front cover. 
II.  Using the 2 mounting holes as a template, mark off the positions in the most appropriate place. 
III.  Insert the wall plugs if fixing into plaster or brick surface. 
IV.  Screw the Keypad onto the wall plugs.   
V.  Replace the 2 slide-out sections.   

z

z

 

 

H

H

o

o

w

w

 

 

t

t

o

o

 

 

S

S

e

e

t

t

 

 

S

S

y

y

s

s

t

t

e

e

m

m

 

 

M

M

o

o

d

d

e

e

:

:

 

 

Arm/Home with Pin Code 

¾

 

Arm Mode

: Enter anyone of Control Panel user codes and press 

  key. Red TX LED will flash 5 

times and the Keypad sounds a long beep. 

¾

 

Home Mode

: Enter anyone of Control Panel user codes and press

 

  key. Red TX LED will flash 5 

times and the Keypad sounds 3 beeps. 

¾

 

Disarm Mode

: Enter anyone of Control Panel user codes and press

 

  key. Red TX LED will flash 5 

times and the Keypad sounds 2 beeps. 

¾

 

Enter Test Mode — Enter Keypad PIN code and press 

* 

key. The Keypad will sound 1 long beep and 

Green Active LED flashes steadily. 

¾

 

Panic Alarm — Press 

1

 + 

3

 simultaneously at the same time. Red TX LED will flash 5 times and the 

Keypad sounds a long beep. 

¾

 

Fire Alarm — Press 

4

 + 

6

 simultaneously at the same time. Red TX LED will flash 5 times and the 

Keypad sounds a long beep. 

¾

 

Medical Alarm — Press 

7

 + 

9

 simultaneously at the same time. Red TX LED will flash 5 times and the 

Keypad sounds a long beep. 

¾

 

For wrong entering or operating the Keypad will sound 4 short beeps. 

Arm/ Home without PIN Code 

¾

 

Arm Mode

: Press 

  key. Red TX LED will flash 5 times and the Keypad sounds a long beep. 

¾

 

Home Mode

: Press 

 key.

 

Red TX LED will flash 5 times and the Keypad sounds 3 beeps. 

¾

 

Disarm Mode

: Enter anyone of Control Panel user codes and 

  Key. Red TX LED will flash 5 times 

and the Keypad sounds 2 beeps. 

Содержание KP-15

Страница 1: ...e LED flash the system is in Test Mode z When the Keypad is idle all LEDs are off After any key press the G Gr re ee en n Active LED turns on for 5 seconds indicating that Keypad is active z T Th he e G Gr re ee en n Active LED will turn off after successful completion of a valid keystroke sequence or when the pause in between key stokes is longer than 5 seconds z When the G Gr re ee en n Active L...

Страница 2: ... T Te es st t m mo od de e z Keypad can be put into Test mode by entering the PIN code default 0000 followed by The Green Active LED will flash and Keypad sounds a long beep z To exit Test mode press twice Keypad will sound a long beep and the Green Active LED will turn on then Keypad returns to Normal Operation mode N NO OT TE E When Keypad is in Test mode it operates as wake up condition thus wi...

Страница 3: ...nting holes as a template mark off the positions in the most appropriate place III Insert the wall plugs if fixing into plaster or brick surface IV Screw the Keypad onto the wall plugs V Replace the 2 slide out sections z z H Ho ow w t to o S Se et t S Sy ys st te em m M Mo od de e Arm Home with Pin Code Arm Mode Enter anyone of Control Panel user codes and press key Red TX LED will flash 5 times ...

Страница 4: ...pen the Keypad by loosening the 2 fixing screw located behind the Keypad IV Take out the old battery and wait for 5 minutes before replacing the new battery in the battery compartment with unmarked negative side of battery facing down V Close the case using the rear fixing screws VI Screw back the Keypad to the surface with mounting screws and then re insert the slide outs VII Put the Control Pane...

Страница 5: ...If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from...

Отзывы: