CLIMAVENETA i-LIFE SLIM 102 Скачать руководство пользователя страница 5

5

EN 05/2013  

i-LIFE SLIM

i-LIFE SLIM DLIU built-in fan coil
Dimensions

102

202

302

402

502

A

mm

525

725

925

1125

1325

OVERALL DIMENSIONS 

I

126

590

A

63,5

47

80

PACKAGING

I A

 

 

 

 

   

     

     

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

       

   

   

The units are delivered in standard packaging comprising a
cardboard box on pallets; the accessories are supplied sep-
arately,  unassembled,  or  already  fitted  on  the  unit  (upon
request).

DATI COSTRUTTORE (società costruttrice):

COSTRUTTORE S.R.L. – VIA XY – INDIRIZZO XY – CITTA’ XY

Modello della macchina

XYZ-XYZ

Codice di identificazione

00123/01/2001

MODELLO 

 

10 

20 

30 

40 

50 

60 

70

Potenza frigorifera 

kW 

12 

15 

17 

34 

56 

77 

84

Potenza termica 

KW 

23 

33 

43 

53 

63 

65 

90

Portata aria 

mc  

330  550  670  750 

770 

850  910

Assorbimento elettrico  W 

18 

20 

45 

90 

120 

150  150

Corrente assorbita 

4

Data di produzione

15 / 10 / 2001

Lotto di produzione

1937 / 2001

Inside  the  unit  is  an  envelope  containing  the  user,  installa-
tion  and  maintenance  manual. An  identification  label  is
affixed to each individual unit, describing:
• Manufacturer’s details
• Model of the unit and part/serial number
• Wiring diagrams

STORAGE ON SITE

I A

The units must be stored indoors!

Содержание i-LIFE SLIM 102

Страница 1: ...Fan coil with casing or for built in installation with tangential fan and inverter controlled brushless motor EN i LIFE SLIM 102 502 INSTALLATION USER MAINTENANCE MANUAL...

Страница 2: ...llation procedure 6 Minimum installation clearance 6 Dismantling assembling the casing 7 Vertical installation 7 Horizontal installation 8 Fixing the front intake grill 8 Front grill safety support as...

Страница 3: ...appliance These appliances have been designed for cooling and heating rooms and must be used in applications compat ible with their performance characteristics Incorrect installation adjustment and m...

Страница 4: ...SPECIFICATIONS i LIFE SLIM 102 202 302 402 502 Coil water content l 0 47 0 8 1 13 1 46 1 8 Maximum operating pressure bar 10 10 10 10 10 Maximum water inlet temperature C 80 80 80 80 80 Minimum water...

Страница 5: ...a macchina XYZ XYZ Codice di identificazione 00123 01 2001 MODELLO 10 20 30 40 50 60 70 Potenza frigorifera kW 12 15 17 34 56 77 84 Potenza termica KW 23 33 43 53 63 65 90 Portata aria mc 330 550 670...

Страница 6: ...ion at the intake and outlet the wall where the unit is installed should be an outside perimeter wall so as to be able to drain the conden sate outside in the event of ceiling installation DLMO or DLI...

Страница 7: ...ing the mouldings Use the paper template and trace the position of the two fastening brackets on the wall Drill the holes with a suitable drill bit and insert the anchors 2 for each bracket fasten the...

Страница 8: ...re available as accessories DLRV versions must not be installed horizontally Carefully check the slope of the drain pipe If the drain line is not sloping downwards water may leak from the line A A B B...

Страница 9: ...provided in the bag supplied together with the instruction booklet and the accessories These supports are designed to stop the grill from falling Separate the two clamps open the front grill and comp...

Страница 10: ...it the pump underneath the side drain pan for horizontal installation the position of the pump should be determined according to specific needs These pumps are widely available on the market In any ca...

Страница 11: ...nd return pipes all the way to the unit so as to prevent condensate from dripping out side of the collection pan insulate the entire condensate pan drain pipe A A FILLING THE SYSTEM I A A Coil vent Wh...

Страница 12: ...the Technical Service and using orig inal spare parts when required CLEANING THE OUTSIDE OF THE UNIT I A Before any cleaning and maintenance work disconnect the unit from the mains power supply switch...

Страница 13: ...tom edge is correctly fitted in place Never use the appliance without the mesh filter The appliance is fitted with a safety switch that prevents the fan from operating if the panel is not fitted or is...

Страница 14: ...d make sure the fan can spin freely The microswitch that stops the fan when opening the filter grill does not close correctly Make sure that when closing the grill the microswitch contact is activated...

Страница 15: ...COD C01002328A_02...

Отзывы: