FUNDAMENTAL SAFETY RULES

U I A

When operating equipment involving the use of electricity and water, a number of fundamental safety rules must be observed,
namely: 

The appliance is not intended for use by persons (includ-
ing  children)  with  reduced  physical,  sensory  or  mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concern-
ing use of the appliance by a person responsible for their
safety.
Children must be supervised to ensure they do not play
with the appliance.
Installation must only be performed by qualified person-
nel.

Do not touch the unit with bare feet or with wet or damp
parts of the body.

Never  perform  any  cleaning  operations  before  having
disconnected  the  unit  from  the  mains  power  supply,
moving the main switch to the “off” position.

Do not modify safety or control devices without authori-
sation and instructions from the manufacturer.

Do not pull, detach or twist the electrical cables coming
from  the  unit,  even  when  disconnected  from  the  mains
electricity supply.

Do  not  introduce  objects  or  substances  through  the  air
outlet and intake grills.

Do  not  open  doors  or  panels  providing  access  to  the
internal  parts  of  the  appliance,  without  first  having
moved the main switch to “off”.

Do not dispose of, abandon or leave within reach of chil-
dren packaging materials, as they may represent a haz-
ard.

Do not sit or stand on the appliance and/or rest any type
of object on top of it.

The  outside  components  of  the  appliance  may  reach
temperatures exceeding 70°

GENERAL WARNINGS

After  having  removed  the  packing,  check  that  the  con-
tents are intact and complete. 
In the event of discrepancies, contact the service centre
that sold the appliance. 

The appliances must be installed by authorised personnel,
who  at  the  end  of  the  work  shall  issue  a  declaration  of
conformity in compliance with the legislation in force and
with the instructions provided in the booklet supplied with
the appliance.

These  appliances  have  been  designed  for  cooling  and
heating rooms and must be used in applications compat-
ible with their performance characteristics.
Incorrect  installation,  adjustment  and  maintenance  or
improper use absolve the manufacturer from all liability,
whether contractual or otherwise, for damage to people,
animals or things.

In the event of water leaks, move the main system switch
to the “off” position and close the water taps.
Contact the technical service or a qualified professional
as soon as possible. Do not attempt to repair the appli-
ance yourself.

Built-in fan coils are supplied without grills and casing. 
Protective covers and air outlet/intake grills must be pro-
vided, to prevent accidental contact with the appliance. 

The fan coils with casing are equipped with automatically
adjustable air outlet louvers. For correct operation of the
louvers both when opening and closing, make sure there
is  nothing  that  impedes  their  movement.  For  trou-
bleshooting information, see the corresponding chapter.

If the appliance is not used for a long period, proceed as
follows:
- Move the main system switch to the “off” position
- Close the water taps
-  If  there  is  the    risk  of  freezing,  empty  the  system  or

make sure it antifreeze is added.

Excessively low or high temperatures are harmful to the
health and a useless waste of energy.
Avoid extended direct contact with the air flow.

Do not leave the rooms closed for too long. 
Periodically open windows to ensure correct air change.

This instruction booklet is an integral part of the appliance
and  must  therefore  be  kept  carefully  and  must ALWAYS
accompany the appliance if sold to another owner or user,
or transferred to another system.
If this booklet is lost or damaged, contact your local Tech-
nical Service for a replacement.

All  repair  or  maintenance  work  must  be  carried  out  by
the company's Technical Service or qualified personnel,
following the instructions in this booklet. Do not modify or
tamper  with  the  appliance  as  this  may  create  situations
of  danger;  in  such  cases  the  manufacturer  of  the  appli-
ance is not liable for any damage caused.

Pay careful attention to avoiding contact: danger of burns.

U I A

Содержание i-LIFE SLIM 102

Страница 1: ...Fan coil with casing or for built in installation with tangential fan and inverter controlled brushless motor EN i LIFE SLIM 102 502 INSTALLATION USER MAINTENANCE MANUAL...

Страница 2: ...llation procedure 6 Minimum installation clearance 6 Dismantling assembling the casing 7 Vertical installation 7 Horizontal installation 8 Fixing the front intake grill 8 Front grill safety support as...

Страница 3: ...appliance These appliances have been designed for cooling and heating rooms and must be used in applications compat ible with their performance characteristics Incorrect installation adjustment and m...

Страница 4: ...SPECIFICATIONS i LIFE SLIM 102 202 302 402 502 Coil water content l 0 47 0 8 1 13 1 46 1 8 Maximum operating pressure bar 10 10 10 10 10 Maximum water inlet temperature C 80 80 80 80 80 Minimum water...

Страница 5: ...a macchina XYZ XYZ Codice di identificazione 00123 01 2001 MODELLO 10 20 30 40 50 60 70 Potenza frigorifera kW 12 15 17 34 56 77 84 Potenza termica KW 23 33 43 53 63 65 90 Portata aria mc 330 550 670...

Страница 6: ...ion at the intake and outlet the wall where the unit is installed should be an outside perimeter wall so as to be able to drain the conden sate outside in the event of ceiling installation DLMO or DLI...

Страница 7: ...ing the mouldings Use the paper template and trace the position of the two fastening brackets on the wall Drill the holes with a suitable drill bit and insert the anchors 2 for each bracket fasten the...

Страница 8: ...re available as accessories DLRV versions must not be installed horizontally Carefully check the slope of the drain pipe If the drain line is not sloping downwards water may leak from the line A A B B...

Страница 9: ...provided in the bag supplied together with the instruction booklet and the accessories These supports are designed to stop the grill from falling Separate the two clamps open the front grill and comp...

Страница 10: ...it the pump underneath the side drain pan for horizontal installation the position of the pump should be determined according to specific needs These pumps are widely available on the market In any ca...

Страница 11: ...nd return pipes all the way to the unit so as to prevent condensate from dripping out side of the collection pan insulate the entire condensate pan drain pipe A A FILLING THE SYSTEM I A A Coil vent Wh...

Страница 12: ...the Technical Service and using orig inal spare parts when required CLEANING THE OUTSIDE OF THE UNIT I A Before any cleaning and maintenance work disconnect the unit from the mains power supply switch...

Страница 13: ...tom edge is correctly fitted in place Never use the appliance without the mesh filter The appliance is fitted with a safety switch that prevents the fan from operating if the panel is not fitted or is...

Страница 14: ...d make sure the fan can spin freely The microswitch that stops the fan when opening the filter grill does not close correctly Make sure that when closing the grill the microswitch contact is activated...

Страница 15: ...COD C01002328A_02...

Отзывы: