![CLIMAVENETA BRA2 0021 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/climaveneta/bra2-0021/bra2-0021_installation-user-and-maintenance-manual_2624863017.webp)
17
BRA2 - BRN2
EN
GENERAL TECHNICAL DATA
I A
BRN2 without hydronic kit
0021
0025
0031
0041
0021
0025
0031
0041
0051
0061
Heating capacity
1
[kW]
6,76
8,37
10,5
12,9
6,73
8,3
10,00
13,4
14,8
17,3
Power consumption
1
[kW]
2,25
2,84
3,48
4,35
2,24
2,69
3,23
4,47
4,67
5,58
COP
1
3,01
2,95
3,01
2,97
3,01
3,08
3,10
2,99
3,17
3,10
Cooling capacity
2
[kW]
4,81
5,89
7,29
9,6
4,80
5,99
7,35
10,0
11,1
13,0
Power consumption
2
[kW]
1,96
2,39
3,27
3,81
1,92
2,27
2,99
3,95
4,42
4,95
EER
2
2,45
2,46
2,23
2,51
2,50
2,64
2,46
2,52
2,51
2,63
ESEER
1
3,07
3,05
2,87
3,03
3,09
3,29
2,99
3,09
2,85
3,11
Flow-rate
1
m3/h
1,16
1,44
1,80
2,22
1,16
1,43
1,72
2,30
2,55
2,98
Pressure drop
1
kPa
10
12
13
23
10
12
12
25
24
24
Flow-rate
2
m
3
/h
0,83
1,01
1,25
1,64
0,83
1,03
1,26
1,71
1,91
2,24
Pressure drop
2
kPa
5
6
6
13
5
6
6
14
14
14
Sound power
4
[dBA]
75
75
75
77
75
75
75
77
77
77
Power supply
V-N/Ph-Hz
230-1N-50
400-3N-50
No. of compressors
1
1
1
1
1
1
1
1
1
1
No. of circuits
1
1
1
1
1
1
1
1
1
1
Type of compressor
Scroll
No. of fans
1
1
1
2
1
1
1
2
2
2
Air flow-rate
1
[m
3
/h]
3000
3400
3400
6450
3000
3400
3400
6450
6000
6350
No. of system heat exchangers
1
1
1
1
1
1
1
1
1
1
Type of system heat exchanger
PIASTRE
System water heat exchanger content
l
2
2
2
2
2
2
2
2
2
3
BRN2 with hydronic kit
0021
0025
0031
0041
0021
0025
0031
0041
0051
0061
Heating capacity
1
[kW]
6,72
8,32
10,4
12,8
6,68
8,2
9,99
13,3
14,8
17,2
Power consumption
1
[kW]
2,18
2,75
3,38
4,22
2,17
2,61
3,14
4,38
4,57
5,46
COP
1
3,08
3,02
3,08
3,03
3,08
3,16
3,18
3,04
3,24
3,15
Cooling capacity
2
[kW]
4,83
5,93
7,33
9,6
4,82
6,03
7,39
10,0
11,2
13,1
Power consumption
2
[kW]
1,92
2,34
3,19
3,76
1,88
2,22
2,91
3,88
4,38
4,85
EER
2
2,51
2,53
2,30
2,56
2,56
2,72
2,54
2,58
2,56
2,70
ESEER
1
3,17
3,17
2,97
3,09
3,19
3,43
3,09
3,14
2,93
3,20
Flow-rate
1
m
3
/h
1,16
1,43
1,79
2,20
1,15
1,42
1,72
2,29
2,55
2,96
Available pressure head
1
kPa
66
58
48
46
66
58
51
44
44
40
Flow-rate
2
m
3
/h
0,83
1,02
1,26
1,65
0,83
1,04
1,27
1,72
1,93
2,25
Available pressure head
2
kPa
74
73
67
56
74
73
67
55
55
55
Sound power
[dBA]
75
75
75
77
75
75
75
77
77
77
Power supply
V-N/Ph-Hz
230-1N-50
400-3N-50
No. of compressors
1
1
1
1
1
1
1
1
1
1
No. of circuits
1
1
1
1
1
1
1
1
1
1
Type of compressor
Scroll
No. of fans
1
1
1
2
1
1
1
2
2
2
Air flow-rate
[m
3
/h]
3000
3400
3400
6450
3000
3400
3400
6450
6000
6350
No. of system heat exchangers
1
1
1
1
1
1
1
1
1
1
Type of system heat exchanger
PLATE
System water heat exchanger content
l
2
2
2
2
2
2
2
2
2
3
(1) outside air 7°C; condenser water in/out 40/45°C
(2) outside air 35°C; evaporator water IN/OUT 12/7°C
(3) maximum and minimum operating pressure refer to activation of the pressure switches
(4) Sound power based on measurements performed in accordance with ISO 9614 and Eurovent 8/1
Performance in accordance with EN 14511:2013
(1) outside air 7°C; condenser water in/out 40/45°C
(2) outside air 35°C; evaporator water IN/OUT 12/7°C
(3) maximum and minimum operating pressure refer to activation of the pressure switches
(4) Sound power based on measurements performed in accordance with ISO 9614 and Eurovent 8/1
Performance in accordance with EN 14511:2013
Содержание BRA2 0021