R e s i d e n t i a l Tr a n q u i l i t y
®
2 7 S p l i t ( T T S ) - 6 0 H z H F C - 4 1 0 A
R e v. : 8 M a y, 2 0 1 4 C
c l i m a t e m a s t e r. c o m
7
Equipment Selection
Table 1a: Tranquility
®
27 Carrier/Bryant Air Handler Matches for AHRI Performance
Compressor Section
026
038
049
064
Air Handler
Model FV4
003
005
006
006
Refrigerant
HFC-410A
Metering Device
TXV (required)
Air Coil
Type
Rows - Fins/in.
Face Area (sq. ft.)
Slope
3 - 14.5
3.46
A
3 - 14.5
5.93
A
3 - 14.5
7.42
A
3 - 14.5
7.42
Cabinet Con
fi
gura-
tion
Up
fl
ow/Down
fl
ow/Horizontal (Multipoise)
ECM Settings for
AHRI Ratings
(FV4 Fan Coil)
AC/HP size: 036
System Type:
Comfort AC/HP
CFM Adjust: Nom
AC/HP size: 036
System Type:
HP-E
ffi
c AC/HP
CFM Adjust: High
AC/HP size: 048
System Type:
Comfort AC/HP
CFM Adjust: High
AC/HP size: 060
System Type:
Comfort AC/HP
CFM Adjust: High
Fan Motor Type - HP
ECM - 1/2
ECM - 1/2
ECM - 3/4
ECM - 3/4
Table 1c:
Tranquility
®
27 Air Handler Characteristics for Brands other than Above Models
Model*
Nominal
Tons*
Evaporator
Temp (ºF)
CFM
Capacity
(MBtuh)**
026 - Part Load
1.5
50
530
19.2 - 22.4
026 - Full Load
2.0
52
880
24.2 - 28.2
038 - Part Load
2.5
51
700
25.2 - 29.2
038 - Full Load
3.0
50
1200
34.5 - 40.1
049 - Part Load
3.5
47
1000
34.3 - 39.9
049 - Full Load
4.0
48
1650
46.3 - 53.8
064 - Full Load
5.0
48
1850
54.5 - 63.3
* Nominal tons are at AHRI/ISO 13256-1 GLHP conditions. Two-stage units may be operated in single-stage mode if desired, where smaller capacity is required.
For example, a model 026 may be used as a 1-1/2 ton unit if “locked” into 1st stage operation only. If PSC fan is used, unit must be “locked” into either 1st or
2nd stage. An ECM fan is required for two-stage operation and for AHRI ratings. Size air handler for “Full Load” if operating in two-stage mode.
**When selecting an air handler based upon the above conditions, choose entering WB temperature of 67ºF. Use evaporator temperature, CFM and capacity
requirements as listed above. The air handler capacity must be at least at the minimum capacity shown in the table in order for the AHRI rating condition to be
valid. See Figure 1 for an example selection.
Table 1b: Tranquility
®
27 Rheem/Ruud Air Handler Matches for AHRI Performance
Compressor Section
026
038
049
064
Air Handler Model
RHPL-HM2421
RHPL-HM3621
RHPL-HM24
RHPL-HM6024
Refrigerant
HFC-410A
Metering Device
TXV (Non Bleed) required
Air Coil
Type
Rows - Fins/in.
Face Area (sq. ft.)
N Style
2 - 16 fpi
5.7
N Style
2 - 16 fpi
5.7
N Style
2 - 16 fpi
8.55
N Style
3 - 14 fpi
9.98
Cabinet Con
fi
guration
Up
fl
ow/Down
fl
ow/Horizontal (Multiposition)
ECM Settings
Rheem Comfort
Control System
Rheem Comfort
Control System
Rheem Comfort
Control System
Rheem Comfort
Control System
Fan Motor Type - HP
ECM - 1/3 HP
ECM - 1/2 HP
ECM - 3/4 HP
ECM - 3/4 HP