background image

C L I M A T E M A S T E R   W A T E R - S O U R C E   H E A T   P U M P S

N (ERV) Series

R e v. :   0 4   A p r i l ,   2 0 1 4

14

C l i m a t e M a s t e r   Wa t e r - S o u r c e   H e a t   P u m p s

CLIMA

TE MASTER, INC.

LIMITED EXPRESS 

W

ARRANTY/ LIMIT

A

TION OF

 REMEDIES 

AND LIABILITY

It is expressly understood that unless a statement is speci

fi

 cally 

identi

fi

 ed as a warranty

, statements made by Climate Master

, Inc., a Delaware corporation, (“CM”) or its representatives, relating to 

CM’

s products, whether oral, 

written or contained in any sales literature, catalog or any other agreement, are not express warranties and do not form a part

 of the basis of the bar

gain, but are merely CM’

s opinion or commendation of CM’

s products.

EXCEPT

 AS SPECIFICALL

Y

 SET

 FOR

TH HEREIN, 

THERE IS NO EXPRESS 

W

ARRANTY

 AS 

T

ANY

 OF

 CM’S PRODUCTS. CM MAKES NO 

W

ARRANTY

 AGAINST

 LA

TENT

 DEFECTS. CM MAKES 

NO 

W

ARRANTY

 OF

 MERCHANT

ABILITY

 OF

 THE GOODS OR OF

 THE FITNESS OF

 THE GOODS FOR 

ANY

 P

AR

TICULAR PURPOSE.

GRANT

 OF

 LIMITED EXPRESS 

W

ARRANTY

CM warrants CM products purchased and retained in the United States of 

America and Canada to be free from defects in material a

nd workmanship under normal use and maintenance as follows: (1) 

All complete air condition-

ing, heating and/or heat pump units built or sold by CM for twelve (12) months from date of unit start up or eighteen (18) mont

hs from date of shipment (from factory), whichever comes 

fi

 rst; (2) Repair and replacement parts, 

which are not supplied under warranty

, for nintey (90) days from date of shipment (from factory).  

All parts must be returned t

o CM’

s factory in Oklahoma City

, Oklahoma, freight prepaid, no later than sixty (60) days after 

the date of the failure of the part; if CM determines the part to be defective and within CM’

s Limited Express 

W

arranty

, CM sha

ll, when such part has been either replaced or repaired, return such to a factory recognized dealer

contractor or service or

ganization, F

.O.B. CM’

s factory

, Oklahoma City

, Oklahoma, freight prepaid. 

The warranty on any parts re

paired or replaced under warranty expires at the end of the original warranty period.

This warranty does not cover and does not apply to: (1) 

Air 

fi

 lters, fuses, refrigerant, 

fl

 uids, oil; (2) Products relocated after initial installation; (3) 

Any portion or component of any system that is not supplied 

by CM, regardless 

of the cause of the failure of such portion or component; (4) Products on which the unit identi

fi

 cation tags or labels have been removed or defaced; (5) Products on which payment to CM is or has been in default; (6) Product

which have defects or damage which result from improper installation, wiring, electrical imbalance characteristics or maintenan

ce; or are caused by accident, misuse or abuse, 

fi

 re, 

fl

 ood, alteration or misapplication of the prod-

uct; (7) Products which have defects or damage which result from a contaminated or corrosive air or liquid supply

, operation at

 abnormal temperatures, or unauthorized opening of refrigerant circuit; (8) Mold, fungus or bacteria 

damages; (9) Products subjected to corrosion or abrasion; (10) Products manufactured or supplied by others; (1

1) Products which

 have been subjected to misuse, negligence or accidents; (12) Products which have been operated 

in a manner contrary to CM’

s printed instructions; or (13) Products which have defects, damage or insuf

fi

 cient performance as a result of insuf

fi

 cient or incorrect system design or the improper application of CM’

s products.

CM is not responsible for: (1) 

The costs of any 

fl

 uids, refrigerant or other system components, or associated labor to repair or replace the same, which is incurred as a result

 of a defective part covered by CM’

s Limited Express 

W

arranty;  (2) 

The costs of labor

, refrigerant, materials or service incurred in removal of the defective part, or in obtaining

 and replacing the new or repaired part; or

, (3) 

T

ransportation costs of the defective part from the installa-

tion site to CM or of the return of any part not covered by CM’

s Limited Express 

W

arranty

.

Limitation:

 This Limited Express 

W

arranty is given in lieu of all other warranties. If, notwithstanding the disclaimers contained herein, 

it is determined that other warranties exist, any such warranties, including without limita-

tion any express warranties or any implied warranties of 

fi

 tness for particular purpose and merchantability

, shall be limited to the duration of the Limited Express 

W

arranty

.

LIMIT

A

TION OF

 REMEDIES

In the event of a breach of the Limited Express 

W

arranty

, CM will only be obligated at CM’

s option to repair the failed part or

 unit or to furnish a new or rebuilt part or unit in exchange for the part or unit which has failed. If 

after written notice to CM’

s factory in Oklahoma City

, Oklahoma of each defect, malfunction or other failure and a reasonable n

umber of attempts by CM to correct the defect, malfunction or other failure and the remedy fails 

of its essential purpose, CM shall refund the purchase price paid to CM in exchange for the return of the sold good(s). Said re

fund shall be the maximum liability of CM. 

THIS REMEDY

 IS 

THE SOLE 

AND EXCLUSIVE 

REMEDY

 OF

 THE BUYER OR 

THEIR PURCHASER 

AGAINST

 CM FOR BREACH OF

 CONTRACT

, FOR 

THE BREACH OF

 ANY

 W

ARRANTY

 OR FOR CM’S NEGLIGENCE

 OR IN STRICT

 LIABILITY

.

LIMIT

A

TION OF

 LIABILITY

CM shall have no liability for any damages if CM’

s performance is delayed for any reason or is prevented to any extent by any e

vent such as, but not limited to: any war

, civil unrest, government restrictions or restraints, strikes 

or work stoppages, 

fi

 re, 

fl

 ood, accident, shortages of transportation, fuel, material, or labor

, acts of God or any other reason beyond the sole control 

of CM. 

CM EXPRESSL

Y

 DISCLAIMS 

AND EXCLUDES 

ANY

 LIABIL-

ITY

 FOR CONSEQUENTIAL

 OR INCIDENT

AL

 DAMAGE IN CONTRACT

, FOR BREACH OF

 ANY

 EXPRESS OR IMPLIED 

W

ARRANTY

, OR IN 

T

OR

T

, WHETHER FOR 

CM’

s NEGLIGENCE OR 

AS 

STRICT

 LIABILITY

.

OBT

AINING W

ARRANTY

 PERFORMANCE

Normally

, the contractor or service or

ganization who installed the products will provide warranty performance for the owner

. Sh

ould the installer be unavailable, contact any CM recognized dealer

, contractor or service or

ganiza-

tion. If assistance is required in obtaining warranty performance, write or call:

Climate Master

, Inc. • Customer Service • 7300 S.W

. 44th Street • Oklahoma City

, Oklahoma 73179  (405) 745-6000

NOTE: Some states or Canadian provinces do not allow limitations on how long an implied warranty lasts, or the limitation or ex

clusions of consequential or incidental damages, so the foregoing exclusions and limitations may 

not apply to you. 

This warranty gives you speci

fi

 c legal rights, and you may also have other rights which vary from state to state and from Canadian province to Canadian provi

nce.

Please refer to the CM Installation, Operation and Maintenance Manual for operating and maintenance instructions.

                    

  

 *LC083*

  

Rev

.:  1

1/09 

LC083 

Содержание NB Series

Страница 1: ...ame work In winter the ERV adsorbs heat and moisture from the exhaust air stream during one half of a complete rotation and gives them back to the cold drier intake air supply during the other half rotation In summer the process is automatically reversed Heat and moisture are absorbed from incoming fresh air supply and transferred to the exhaust air stream This process allows outdoor air ventilati...

Страница 2: ...CL IM ATEM ASTER WATER SOURCE HEAT PUMPS N ERV Series Rev 04 April 2014 2 ClimateMaster Water Source Heat Pumps This Page Intentionally Left Blank ...

Страница 3: ...ing or an earth ground NOTE Unit voltage entries must be sealed weather tight after wiring is complete 9 Remove motor access panels Locate belts fastened to blower assembly Install belt onto motor and blower pulley Adjust motor sheave to correct blower RPM for CFM and external static pressure requirements See charts in this instruction Multiple pulley arrangements are available to meet the entire ...

Страница 4: ...hen the supply blower is off to avoid depressurization should be considered FROST THRESHOLD TEMPERATURE INDOOR RH AT 70ºF FROST THRESHOLD TEMPERATURE 20 0ºF 30 5ºF 40 10ºF Recovery Wheel Mode On a thermostat call for blower operation in heating cooling or continuous blower the ERW will rotate between fresh air and exhaust air streams Both the fresh air and exhaust air blowers will also be operatin...

Страница 5: ...f hand pressure does not fully seat the segment insert the flat tip of a screw driver between the wheel rim and outer corners of the segment and apply downward force while guiding the segment into place D Close and latch each segment retainer under segment retaining catch E Slowly rotate the wheel 180º Install the second segment opposite the first for counterbalance Rotate the two installed segmen...

Страница 6: ...P 5 Filter rack with 2 pleated filters included ERV with Horizontal Ductwork balancing damper s field supplied B C D D E I G H F H A D D I K J ERV Data Dimensional Data ERV Series CFM Range A B C D E F G H I J K NB 300 1100 56 75 32 13 39 50 11 00 27 00 4 50 10 00 2 56 1 00 10 00 4 50 NC 1200 2000 54 38 37 25 37 50 12 00 30 00 8 00 4 00 3 63 1 50 7 00 5 00 ND 1200 2800 60 00 42 62 43 56 14 00 32 0...

Страница 7: ...e Control Harness Optional J40 Jack Cycle Optional J48 Jack Control Box Fresh Air J50 Jack Control Box Wheel J51 Jack Control Box Exhaust Air J56 Jack Control Box Damper J148 Jack Fresh Air Motor Harness J150 Jack Wheel Motor Harness J151 Jack Exhaust Air Motor Harness J160 Jack Damper Motor Harness K94 Relay On O Optional K163 Contactor Exhaust Air Motor K164 Contactor Fresh Air Motor P33 Plug Cy...

Страница 8: ...k Cycle Optional J48 Jack Control Box Fresh Air J50 Jack Control Box Wheel J51 Jack Control Box Exhaust Air J56 Jack Control Box Damper J148 Jack Fresh Air Motor Harness J150 Jack Wheel Motor Harness J151 Jack Exhaust Air Motor Harness J152 Jack Transformer High Voltage J160 Jack Damper Motor Harness K94 Relay On Off Optional K163 Contactor Exhaust Air Motor K164 Contactor Fresh Air Motor P33 Plug...

Страница 9: ...es 1 Remove jumper to install field optional low ambient switch 2 Selective voltage terminals for proper unit voltage 3 Optional low ambient switch 4 Optional motorized intake damper 5 Optional Stop Start and Jog Control 6 For energy management systems connect 24v to G and common 24v to C 208 230V 1 PH Desiccant Wheel for Roof top Unit ...

Страница 10: ... Wheel for Roof top Unit Notes 1 Remove jumper to install field optional low ambient switch 2 Step down transformer assembly for 460 575 volt units 3 Selective voltage terminals for proper unit volt age 4 Optional low ambient switch 5 Optional motorized intake damper 6 Optional Stop Start and Jog Control 7 For energy management systems connect 24v to G and common 24v to C ...

Страница 11: ...or Filter in Intake Hood 2HP External Static Pressure in water 0 0 25 0 5 0 75 1 1 25 1 5 CFM 1200 990 1075 1220 1380 1480 1605 1720 1400 1030 1165 1280 1410 1520 1620 1740 1600 1135 1250 1340 1445 1570 1665 1760 1800 1240 1330 1425 1550 1625 1720 1785 2000 1295 1405 1540 1615 1705 1760 1830 Barometric Hood 2 Pleated Filters 2HP External Static Pressure in water 0 0 25 0 5 0 75 1 1 25 1 5 CFM 1200...

Страница 12: ... Kit Mist Eliminator Filter in Intake Hood 3HP External Static Pressure in water 0 0 25 0 5 0 75 1 1 25 1 5 CFM 2000 735 860 920 1005 1075 1150 1220 2400 850 945 1030 1090 1110 1215 1265 2800 935 1020 1080 1145 1200 1255 1335 3200 1015 1075 1105 1195 1285 1325 1380 3600 1065 1125 1220 1305 N A N A N A Barometric Hood 2 Pleated Filters 3HP External Static Pressure in water 0 0 25 0 5 0 75 1 1 25 1 ...

Страница 13: ... Mist Eliminator Filter in Intake Hood 5HP External Static Pressure in water 0 0 25 0 5 0 75 1 1 25 1 5 CFM 4600 795 900 960 1010 1090 1135 1165 5000 835 945 1000 1060 1135 1155 1230 5400 895 985 1040 1130 1155 1220 1265 5800 940 1025 1085 1145 1225 1250 1300 6200 990 1070 1105 1210 1245 1290 N A Barometric Hood 2 Pleated Filters 5HP External Static Pressure in water 0 0 25 0 5 0 75 1 1 25 1 5 CFM...

Страница 14: ...cient or incorrect system design or the improper application of CM s products CM is not responsible for 1 The costs of any fl uids refrigerant or other system components or associated labor to repair or replace the same which is incurred as a result of a defective part covered by CM s Limited Express Warranty 2 The costs of labor refrigerant materials or service incurred in removal of the defectiv...

Страница 15: ...THE SMART SOLUTION FOR ENERGY EFFI C I E NC Y N ERV Series Rev 0 4 A pri l 2 0 1 4 15 climatemaster com Notes ...

Страница 16: ...fic information on the current design and specifications Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties but are merely ClimateMaster s opinion or commendation of its products For the latest version of this document go to climatemaster com ClimateMaster is a proud supporter of the Geothermal Exchange Organiza...

Отзывы: