1.   Open the main control 

panel: put the screwdriver 

(3.5mm)   into   the   block

4mm   along   the   bevel.
Prize up, open the clips.

2.   Take off the wires.

3. As per wiring diagram, 

connect it with terminals, 

fixed by the screwdriver.

4. Put the connected 

thermostat onto  the  back 

panel in the wall, then fix it 

with the two screws in the 

packing box.

5.  Put the cover with 30 

degree angle, then fix the 

up two clips;

6. Push the places of the 

two down clips, fix the 

cover, and finish the 

installation.

Содержание HL2025 Series

Страница 1: ...ing and cooling valves and 3 speed fan when the temperature reaches the set point it will close the valves with the fan still running T Clock and timing on off Blank is invalid T74 7 days programming Blank is invalid L Blue backlight E Auto Restart Restart the working status of last 6 seconds before power off Blank is invalid BASIC FEATURES STATUS DISPLAY Room temperature setting Manual or auto 3 ...

Страница 2: ...opened Otherwise it will be closed Heating valve is always closed In heating When the room temperature is lower than set point the heating valve will be opened Otherwise it will be closed Cooling valve is always closed CLOCK CALIBRATION T T74 Press M with four seconds till to display hh mm and hh flash press or to adjust hour press M mm flash press or to adjust minute Press M week flash press or t...

Страница 3: ...ld be automatically locked in 30 seconds Low Temperature Protection Function Turn off When the room temperature is lower than 5 C the thermostat would automatically turn on the fan and valve with showing When the room temperature reaches to 7 C the thermostat will automatically close the output Low Temperature Protection Setting Turn off press and hold for 3 seconds it will display OF or ON press ...

Страница 4: ...crewdriver 3 5mm into the block 4mm along the bevel Prize up open the clips 2 Take off the wires 3 As per wiring diagram connect it with terminals fixed by the screwdriver 4 Put the connected thermostat onto the back panel in the wall then fix it with the two screws in the packing box 5 Put the cover with 30 degree angle then fix the up two clips 6 Push the places of the two down clips fix the cov...

Отзывы: