![Clima-Flex HL2025 Series Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/clima-flex/hl2025-series/hl2025-series_user-manual_2624460003.webp)
Clima-Flex, S.A. de C.V.
Av. Central #285 Parque Industrial Logistico / Delegación la Pila / C.P. 78422 / San Luis Potosí, México
Tel. 52 (444) 161-50-43 Facebook/clima-flex @climaflexMéxico
Week
Period. No. 1
Period. No. 2
Period. No. 3
Period. No. 4
Starting Time/
Temperature
Starting Time/
Temperature
Starting Time/
Temperature
Starting Time/
Temperature
Mon
7:00 25°C
8:00 25°C
18:00 25°C
21:00 25°C
Tue
7:00 25°C
8:00 25°C
18:00 25°C
21:00 25°C
Wed
7:00 25°C
8:00 25°C
18:00 25°C
21:00 25°C
Thu
7:00 25°C
8:00 25°C
18:00 25°C
21:00 25°C
Fri
7:00 25°C
8:00 25°C
18:00 25°C
21:00 25°C
Sat
7:00 25°C
8:00 25°C
18:00 25°C
21:00 25°C
Sun
7:00 25°C
8:00 25°C
18:00 25°C
21:00 25°C
Repeat the above steps to set for TUE, WED, THU, FRI, SAT, SUN.
Keypad Lock Function
»
Keypad Lock: its keypad would be automatically locked in 30 seconds in case that no one uses the thermostat, so as to
prohibit other persons from operating the thermostat.
»
Keypad Unlock: Press“ ”for 5 seconds to unlock (In case that no one uses the thermostat, its keypad would be
automatically locked in 30 seconds).
Low Temperature Protection Function
»
Turn off: When the room temperature is lower than 5°C, the thermostat would automatically turn on the fan and valve with
“
” showing, When the room temperature reaches to 7°C, the thermostat will automatically close the output.
Low Temperature Protection Setting
»
Turn off: press” ” and hold for 3 seconds, it will display “OF” or “ON”, press “▲” or “▼”button to adjust the
parameter. “OF” indicates low temperature protection invalid, “ON” indicates low temperature protection function valid. The
default is “OF”.
Temperature Adjustment
In case that the user wants the displayed temperature on the thermostat higher or lower than the real temperature(±5°C), the
following operations could be taken:
»
Turn off: press “▲” and “▼” at the same time for 3 seconds, it will display “XX °C” (not displaying the working model),
press “▲”or “▼” to adjust the temperature value, it will be automatically confirmed after 6 seconds.
Alarm
»
If the sensor has failure, the thermostat will close the fan and valve, displaying “E1” or “E2”.
E1: Sensor in short circuit alarm
E2: Sensor in open circuit alarm
It displays “HI” when the temperature is higher than 55°C, displaying “LO” when the temperature is lower than 0°C.