type A: positive (+) 12-volt pulse
The system can control Type A door locks directly, with no additional parts. The switch
will have three wires on it; one will test (+)12 volt constantly. The others will alternate-
ly pulse (+)12 volt when the switch is pressed to the lock or unlock position.
If you cannot get to the switch, and you find a set of wires that pulse (+)12 volt alter-
nately on lock and unlock, make sure that it is not a Type C direct-wire system.
Cut the wire that pulses (+)12 volt on lock, and then operate the switch to unlock.
z
If all doors unlock, the vehicle uses type A system.
z
If you lose all door lock operation in both directions, you are operating the mas-
ter switch in a Type C system.
z
If you lose all door lock operation of one or more, but not all motors, and other
doors still work, you have cut a wire leading directly to one or more motors. You
must instead find the actual wires leading to the switch.
IIM
MPPO
ORRTTA
AN
NTT!! Remember that these wires' functions reverse between Type A and Type
B.