© 2004 directed electronics, inc.
25
z
Type G: Positive (+) multiplex resistor-based circuit.
z
Type H: Negative (-) multiplex resistor-based circuit.
at the switch
z
Three-wire switches will have either a constant ground input or a constant
(+)12V input, along with the pulsed lock and unlock outputs to the factory relays.
z
Some vehicles have no external switch. The switches are inside the actuator, and
instead of pulsing, the proper wires will flip-flop from (+)12V to (-) ground as the
door locks are operated.
z
Direct-wired switches will have a (+)12V constant input and one or two (-)
ground inputs, along with two output leads going directly to the lock motors.
type A: positive-triggered, relay-driven system
IIM
MPPO
ORRTTA
AN
NTT!! The H2/1 and H2/6 wires are not required for wiring the door locks.
For detailed wiring instructions for these two wires, refer to the beginning of the Door
Lock Harness (H2) Wire Connection Guide section. Depending on the type of door
lock system, there may be additional H2 harness wires that are not used for wiring the
door locks.
LOCK UNLOCK
H2/1
H2/2
H2/3
H2/4
H2/5
H2/6
ON-BOARD
LOCK
RELAY
#87
#87A
#30
NOT USED
NOT USED
VEHICLE (+)
LOCK TRIGGER
CIRCUIT
VEHICLE (+)
UNLOCK TRIGGER
CIRCUIT
FACTORY LOCK
SWITCH
TO FACTORY
RELAYS
GREEN/BLACK
LOCK #30 COMMON (OUTPUT)
WHITE/BLACK
LOCK #87A NORMALLY CLOSED
VIOLET/BLACK
LOCK #87 NORMALLY OPEN (INPUT)
VIOLET
UNLOCK #87 NORMALLY OPEN (INPUT)
BLUE/BLACK
UNLOCK #30 COMMON (OUTPUT)
15A
VEHICLE FUSED
+12 VOLT CONSTANT
DIA-626
BROWN/BLACK
UNLOCK #87A NORMALLY CLOSED
ON-BOARD
LOCK
RELAY
#87
#87A
#30