www.directed.com
30
type E: electronically-activated vacuum systems
Type E door locks are controlled by an electrically activated vacuum pump. Test by
locking doors from the passenger key cylinder. If all the doors lock, the vehicle's door
lock system can be wired as type E. The control wire can be found in either kick panel
and will show (+)12 volt when doors are unlocked and (-) ground when doors are
locked.
To interface see diagram below. The system must be programmed for 3.5 second door
lock pulses up to model year1993 and 1 second pulse for model year 1994 or newer.
H2/1
H2/2
H2/3
H2/4
H2/5
H2/6
ON-BOARD
LOCK
RELAY
#87
#87A
#30
GREEN/BLACK
LOCK #30 COMMON (OUTPUT)
WHITE/BLACK
LOCK #87A NORMALLY CLOSED
VIOLET/BLACK
LOCK #87 NORMALLY OPEN (INPUT)
BROWN/BLACK
UNLOCK #87A NORMALLY CLOSED
BLUE/BLACK
UNLOCK #30 COMMON (OUTPUT)
VIOLET
UNLOCK #87 NORMALLY OPEN (INPUT)
DIA-632
ON-BOARD
LOCK
RELAY
#87
#87A
#30