INSTALLATION AND OPERATING INSTRUCTIONS  

7

 

 

8.   To select ON/OFF timer.

To set automatic OFF timer, press TIMER button when unit is 
powered ON; select the desired running time, 1 to 24 hours.  
Unit will automatically switch OFF once selected OFF time duration 
has lapsed. The screen will display time elapsed and remaining 
running time.

To set automatic ON timer, press TIMER button when unit is 
powered OFF or on standby mode, select the desired time for unit 
to start operating in 1 to 24 hours. Timer symbol will be displayed 
on screen, and unit will automatically switch on when time is 
reached.

Note:

 Memory function will not work on Timing shutdown.

9.   When unit is powered ON, press SWING to oscillate dry 

air outlet deflector panel from 50 to 95 degree angle 
automatically, LCD will display swing icon 

. Press SWING 

again to fix stationary angle, swing icon will disappear.

10. As unit operates, condensed water will drain into water 

reservoir. When water reservoir is full unit will beep 10 times 
and WATER FULL 

 indicator light will illuminate and all other 

indicator lights will turn orange. Unit will automatically stop 
operating. The water reservoir must be removed and emptied 
before unit will operate again. See Fig 1.

Note:

 Allow minimum of three minutes before turning unit on,  

after water reservoir is emptied.

Fig 1

Remove water 
reservoir in 
accordance with 
arrow direction

Содержание CLI-DH20-E

Страница 1: ...CLI DH20 E Installation Operating Instructions Air Dehumidification System ...

Страница 2: ...sture from the air creating a drier healthier room environment Note Please read through the instructions carefully before using or installing the product and ensure that the manual is kept in a safe place for future reference The system must be properly installed and located in accordance with the installation instructions before it is used During the set up of this product if you have any questio...

Страница 3: ...Units must never be placed and operated on an angle as water spillage from reservoir can occur Empty the water when water reservoir is full or not in use for a prolonged period Recommended operating temperature range is minimum 5 C RH 40 and maximum 35 C RH 90 Any servicing other than cleaning and user maintenance will violate the terms of this WARRANTY and warranty will be null and void Note RH R...

Страница 4: ... unplug unit with wet hands Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions or has been damaged in any manner If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The use of accessory attachments not recommended by the appliance manufacturer may result in fire e...

Страница 5: ...unplug the power cord Ensure unit is dried thoroughly before operation of the unit Do not put fingers or other objects in any openings of the unit During the set up of this product if you have any questions comments issues DO NOT RETURN TO STORE FOR SERVICE AND TECHNICAL ADVICE ON THIS PRODUCT FREE CALL 1300 764 325 ...

Страница 6: ... Air inlet F Air Filter G Continuous Drainage Hose H Continuous Drainage Outlet For hose connection I Water Reservoir Continuous drainage hose is an extra drainage option hose does not need to be connected if using the water reservoir to catch condensed water A COMPONENT IDENTIFICATION AND CHECK LIST G H I A B C ...

Страница 7: ...High H Low L and ambient relative humidity ratios TIMER To set automatic ON OFF timer at 1 to 24 hour settings SWING Turns air deflector ON OFF to allow better distribution of air output C LCD DISPLAY ICONS 1 Automatic Dehumidifying 7 Dehumidifying 2 RH Settings 8 Timer 3 Wind Speed 9 Defrost 4 Water Full 10 Ambient Temperature 5 Ambient Humidity 11 Continuous Dehumidifying 6 Swing T i m e r Setti...

Страница 8: ... unit on automatic dehumidification the continuous dehumidifying mode will be cancelled Note When the ambient relative humidity is 1 lower than the selected relative humidity ratio percentage RH the unit compressor will switch off and fan speed will operate at a Low L Note When the ambient relative humidity is 5 higher than the selected relative humidity ratio percentage RH the unit will switch on...

Страница 9: ...ached Note Memory function will not work on Timing shutdown 9 When unit is powered ON press SWING to oscillate dry air outlet deflector panel from 50 to 95 degree angle automatically LCD will display swing icon Press SWING again to fix stationary angle swing icon will disappear 10 As unit operates condensed water will drain into water reservoir When water reservoir is full unit will beep 10 times ...

Страница 10: ...screen Note Unit will not be operable when sensor is activated to restart unit unplug unit and restart again Note If unit is shut off due to protection of extremely low high temperatures the unit memory function will not operate unit will reset at default setting 3 Failure of Humidity Temperature Sensor When the connection wire between the humidity and temperature sensor is disconnected the humidi...

Страница 11: ...ced over a water drain Note For the unit to drain correctly no part of the hose should be above the level of the water spigot continuous drainage outlet G MAINTENANCE AND REPAIR Before carrying out any maintenance or cleaning of the unit make sure that the power to the unit is turned off and power cord is removed from the power socket External cleaning of unit Do not clean unit with any abrasive c...

Страница 12: ...it empty the water reservoir and allow minimum of two days for unit to dry before packing away Keep unit in a dry and ventilated place Repair If the unit or power cord is damaged stop using immediately and bring the unit to authorised service center for repair never attempt to dismantle repair or modify the unit by yourself Warranty will be null and void ...

Страница 13: ...f problem persists call customer care No Air 1 Unit is not plugged into wall socket 2 Humidity ratio if set has been reached 3 Air outlet blocked 4 Water Reservoir is full 1 Check connection to wall socket 2 Wait 30 minutes turn unit back on 3 Ensure there are no objects obstructing air outlet 4 Empty water reservoir Unit Overheating 1 Air ventilation around unit not sufficient 2 Humid Air Inlet o...

Страница 14: ...ed to spigot properly 3 Continuous drainage hose outlet not over water drain 1 Reinstall water reservoir 2 Check hose connection 3 Check hose outlet is flowing into water drain Beeping Alarm Noise 1 Water Reservoir is Full 2 Ambient temperature is either less than or equal to 0 C or greater than or equal to 40 C 1 Remove and empty water reservoir 2 Turn off unit and restart or if unit is in defros...

Страница 15: ...anship in the manufactured product Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if goods fail to be of acceptable quality and the failure does not amount to a maj...

Страница 16: ...CUSTOMER HOTLINE 1300 764 325 Aquaport Corporation Pty Ltd PO Box 81 Findon SA 5023 Australia Telephone 1300 764 325 Facsimile 08 8354 0722 Email aquaport aquaport com au Web www aquaport com au ...

Отзывы: